{"specs/liberty/zonemanager-parallel-zoning.rst":[{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":19,"context_line":""},{"line_number":20,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":21,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_3ea661ae","line":22,"updated":"2015-05-30 07:54:34.000000000","message":"s/ie/e.g.,\n\nPlease clarify what you mean by \u0027type of switch\u0027 -- assume Brocade vs. Cisco?","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":19,"context_line":""},{"line_number":20,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":21,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_58ea4ddc","line":22,"in_reply_to":"7a016987_3ea661ae","updated":"2015-05-31 03:12:42.000000000","message":"Yes, please clarify.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"a76153d443df7f6a24fc491b48287c7bb28cefc1","unresolved":false,"context_lines":[{"line_number":19,"context_line":""},{"line_number":20,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":21,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "}],"source_content_type":"text/x-rst","patch_set":1,"id":"5afe65bd_8edb9aed","line":22,"in_reply_to":"7a016987_58ea4ddc","updated":"2015-06-01 20:54:21.000000000","message":"Right, I meant switch types for Brocade/Cisco but made the term generic for any switch. I will try to clarify.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":21,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"                      +----------------+"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_feab2973","line":24,"updated":"2015-05-30 07:54:34.000000000","message":"s/call/calls and remove trailing comma","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"                      +----------------+"},{"line_number":28,"context_line":"                      | fc_zone_manager|"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_0532375e","line":25,"updated":"2015-05-29 23:11:20.000000000","message":"Trailing blank space.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":22,"context_line":"switch types, ie. switch_type1/switch_type2 combination."},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"Linear call down for the zone drivers to perform a zoning operation,"},{"line_number":25,"context_line":"limits all switches to use same zone driver. "},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"                      +----------------+"},{"line_number":28,"context_line":"                      | fc_zone_manager|"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_38e55108","line":25,"in_reply_to":"7a016987_0532375e","updated":"2015-05-31 03:12:42.000000000","message":"+1","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":46,"context_line":"There are multiple accesses to a switch for EACH initiator passed to the"},{"line_number":47,"context_line":"ZoneManager. These accesses are for port and zone information."},{"line_number":48,"context_line":""},{"line_number":49,"context_line":"#Example of adding a zone: 2-fabric setup, "},{"line_number":50,"context_line":"target1 \u0026 target3 are connected to switch_type1"},{"line_number":51,"context_line":"target2 \u0026 target4 are connected to switch_type2"},{"line_number":52,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_7eae1982","line":49,"updated":"2015-05-30 07:54:34.000000000","message":"Don\u0027t need the prefix \u0027#\u0027\ns/,/: in trailing character","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":51,"context_line":"target2 \u0026 target4 are connected to switch_type2"},{"line_number":52,"context_line":""},{"line_number":53,"context_line":"initiator-target-map \u003d { \u0027initiator1\u0027: [\u0027target1\u0027, \u0027target2\u0027], "},{"line_number":54,"context_line":"\t\t                 \u0027initiator2\u0027: [\u0027target3\u0027, \u0027target4\u0027}"},{"line_number":55,"context_line":"                    "},{"line_number":56,"context_line":"* On each fabric associated with a target_wwpn value for each initiator_wwpn,"},{"line_number":57,"context_line":"add_zones() will perform a pre-check, _get_active_zone_set(), "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_05091784","line":54,"updated":"2015-05-29 23:11:20.000000000","message":"Please remove tabs.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":51,"context_line":"target2 \u0026 target4 are connected to switch_type2"},{"line_number":52,"context_line":""},{"line_number":53,"context_line":"initiator-target-map \u003d { \u0027initiator1\u0027: [\u0027target1\u0027, \u0027target2\u0027], "},{"line_number":54,"context_line":"\t\t                 \u0027initiator2\u0027: [\u0027target3\u0027, \u0027target4\u0027}"},{"line_number":55,"context_line":"                    "},{"line_number":56,"context_line":"* On each fabric associated with a target_wwpn value for each initiator_wwpn,"},{"line_number":57,"context_line":"add_zones() will perform a pre-check, _get_active_zone_set(), "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_18f055c8","line":54,"in_reply_to":"7a016987_05091784","updated":"2015-05-31 03:12:42.000000000","message":"Missing closing \"]\"","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":70,"context_line":""},{"line_number":71,"context_line":"Zone switches in parallel. Zoning the switches concurrently would reduce the"},{"line_number":72,"context_line":"overall time required to create multiple zones. It would also allow different"},{"line_number":73,"context_line":"switch types to be paired."},{"line_number":74,"context_line":""},{"line_number":75,"context_line":"The ZoneManger would streamline the initialization of "},{"line_number":76,"context_line":"the fabric CLI clients from the registered fabrics. These CLI connections "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_1ec84554","line":73,"updated":"2015-05-30 07:54:34.000000000","message":"Can you give a ballpark decrease in time?  e.g., perhaps list an example time measurement now relative to the improvements you\u0027re predicting?  This will help justify the added complexity.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"a76153d443df7f6a24fc491b48287c7bb28cefc1","unresolved":false,"context_lines":[{"line_number":70,"context_line":""},{"line_number":71,"context_line":"Zone switches in parallel. Zoning the switches concurrently would reduce the"},{"line_number":72,"context_line":"overall time required to create multiple zones. It would also allow different"},{"line_number":73,"context_line":"switch types to be paired."},{"line_number":74,"context_line":""},{"line_number":75,"context_line":"The ZoneManger would streamline the initialization of "},{"line_number":76,"context_line":"the fabric CLI clients from the registered fabrics. These CLI connections "}],"source_content_type":"text/x-rst","patch_set":1,"id":"5afe65bd_c708552b","line":73,"in_reply_to":"7a016987_1ec84554","updated":"2015-06-01 20:54:21.000000000","message":"I\u0027ll try something to run a comparison of the numbers. The first examples conclude there is 10 operation calls to the switches consecutively. The second example with the proposed changes highlights the reduced 6 operation calls to the switch, keep in mind these calls are concurrent. Which roughly equates to 3 sequential calls, a really rough estimation would be 70% decrease in time talking to switches.... but I will try to get some factual numbers.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":99,"context_line":"              "},{"line_number":100,"context_line":"1)Zone information gathering(_get_active_zone_set) would only need to"},{"line_number":101,"context_line":"be accessed once versus multiple times per initiator. "},{"line_number":102,"context_line":"2)Accessing port information(get_san_context) would required half the time."},{"line_number":103,"context_line":"3)Writing to fabric(add_zones) would require half the time."},{"line_number":104,"context_line":""},{"line_number":105,"context_line":"#Example of adding zone:"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_a56b631d","line":102,"updated":"2015-05-29 23:11:20.000000000","message":"\u0027would be required\u0027","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":109,"context_line":"\t1 writes per fabric"},{"line_number":110,"context_line":""},{"line_number":111,"context_line":"* note: "},{"line_number":112,"context_line":"There are WILL ONLY be 2 get_active_zone_set() calls, once for each fabric,"},{"line_number":113,"context_line":"instead of a get_active_zone_set() for each initiator."},{"line_number":114,"context_line":""},{"line_number":115,"context_line":"    "}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_e55b9b84","line":112,"updated":"2015-05-29 23:11:20.000000000","message":"Typo \"There WILL ONLY be ..\"  remove \u0027be\u0027","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":115,"context_line":"    "},{"line_number":116,"context_line":"Alternatives"},{"line_number":117,"context_line":"------------"},{"line_number":118,"context_line":"None"},{"line_number":119,"context_line":""},{"line_number":120,"context_line":"Data Model Impact"},{"line_number":121,"context_line":"-----------------"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_25cd3331","line":118,"updated":"2015-05-29 23:11:20.000000000","message":"Are there really no alternatives?","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"a76153d443df7f6a24fc491b48287c7bb28cefc1","unresolved":false,"context_lines":[{"line_number":116,"context_line":"Alternatives"},{"line_number":117,"context_line":"------------"},{"line_number":118,"context_line":"None"},{"line_number":119,"context_line":""},{"line_number":120,"context_line":"Data Model Impact"},{"line_number":121,"context_line":"-----------------"},{"line_number":122,"context_line":"None"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5afe65bd_c22a832c","line":119,"updated":"2015-06-01 20:54:21.000000000","message":"Will update with some...","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":127,"context_line":""},{"line_number":128,"context_line":"Security Impact"},{"line_number":129,"context_line":"---------------"},{"line_number":130,"context_line":""},{"line_number":131,"context_line":"N/A"},{"line_number":132,"context_line":""},{"line_number":133,"context_line":"Performance Impact"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_9ee2f5d3","line":130,"updated":"2015-05-30 07:54:34.000000000","message":"Extra newline","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":140,"context_line":""},{"line_number":141,"context_line":"Other end user impact"},{"line_number":142,"context_line":"---------------------"},{"line_number":143,"context_line":"None"},{"line_number":144,"context_line":""},{"line_number":145,"context_line":"Other deployer impact"},{"line_number":146,"context_line":"---------------------"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_85f98750","line":143,"updated":"2015-05-29 23:11:20.000000000","message":"End user and/or deployer impact:  If this feature is released it is going to change what users can do with regards to zoning.  They will need to be made aware of that.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":156,"context_line":""},{"line_number":157,"context_line":"Work Items"},{"line_number":158,"context_line":"----------"},{"line_number":159,"context_line":""},{"line_number":160,"context_line":"Dependencies"},{"line_number":161,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":162,"context_line":"None"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_259bf319","line":159,"updated":"2015-05-29 23:11:20.000000000","message":"What are the steps you plan to implemented this?","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":156,"context_line":""},{"line_number":157,"context_line":"Work Items"},{"line_number":158,"context_line":"----------"},{"line_number":159,"context_line":""},{"line_number":160,"context_line":"Dependencies"},{"line_number":161,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":162,"context_line":"None"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_98b20505","line":159,"in_reply_to":"7a016987_259bf319","updated":"2015-05-31 03:12:42.000000000","message":"+1. Need to provide work items.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":163,"context_line":""},{"line_number":164,"context_line":"Testing"},{"line_number":165,"context_line":"\u003d\u003d\u003d\u003d\u003d"},{"line_number":166,"context_line":"There need to  be additional unit test cases for the"},{"line_number":167,"context_line":"supported functionality change"},{"line_number":168,"context_line":""},{"line_number":169,"context_line":"Documentation Impact"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_9e943537","line":166,"updated":"2015-05-30 07:54:34.000000000","message":"Extra space after \u0027to\u0027\ns/need/needs","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":164,"context_line":"Testing"},{"line_number":165,"context_line":"\u003d\u003d\u003d\u003d\u003d"},{"line_number":166,"context_line":"There need to  be additional unit test cases for the"},{"line_number":167,"context_line":"supported functionality change"},{"line_number":168,"context_line":""},{"line_number":169,"context_line":"Documentation Impact"},{"line_number":170,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_78b509eb","line":167,"updated":"2015-05-31 03:12:42.000000000","message":"CI is required for zone drivers now. Assume Brocade and Cisco are working on it. This will go through CI.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":168,"context_line":""},{"line_number":169,"context_line":"Documentation Impact"},{"line_number":170,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_fe744936","line":171,"updated":"2015-05-30 07:54:34.000000000","message":"s/Fiber/Fibre","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7198,"name":"Jay Bryant","email":"jungleboyj@electronicjungle.net","username":"jsbryant"},"change_message_id":"bb1b27f59a749fa77ad65ab64e5413f7c9938329","unresolved":false,"context_lines":[{"line_number":170,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""},{"line_number":175,"context_line":"References"},{"line_number":176,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_e5a03b44","line":173,"updated":"2015-05-29 23:11:20.000000000","message":"How multiple fabrics are set up would have to be documented.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":7664,"name":"Joe Cropper","email":"jwcroppe@us.ibm.com","username":"jwcroppe"},"change_message_id":"fa46c830f3d4109807518ed5d898a63997660b69","unresolved":false,"context_lines":[{"line_number":170,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""},{"line_number":175,"context_line":"References"},{"line_number":176,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_3e7f8116","line":173,"updated":"2015-05-30 07:54:34.000000000","message":"s/Fiber/Fibre","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":170,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""},{"line_number":175,"context_line":"References"},{"line_number":176,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_58d12d22","line":173,"in_reply_to":"7a016987_e5a03b44","updated":"2015-05-31 03:12:42.000000000","message":"+1","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":6491,"name":"xing-yang","email":"xingyang105@gmail.com","username":"xing-yang"},"change_message_id":"c80c3e49e8e8bf018491b1f33588618ddf74e844","unresolved":false,"context_lines":[{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""},{"line_number":175,"context_line":"References"},{"line_number":176,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":177,"context_line":"None"}],"source_content_type":"text/x-rst","patch_set":1,"id":"7a016987_98a9e592","line":174,"updated":"2015-05-31 03:12:42.000000000","message":"Can you provide an example of cinder.conf using both Cisco and Brocade zone drivers? Is this something you\u0027ve already implemented internally?","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"a76153d443df7f6a24fc491b48287c7bb28cefc1","unresolved":false,"context_lines":[{"line_number":171,"context_line":"* Optional- Currently there is a Cisco and Brocade Fiber Channel Zone Driver"},{"line_number":172,"context_line":"page, which documents the configuration settings for connecting to a switch."},{"line_number":173,"context_line":"Would be more accurate to rename as \"Fiber Channel Zone Configuration\""},{"line_number":174,"context_line":""},{"line_number":175,"context_line":"References"},{"line_number":176,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":177,"context_line":"None"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5afe65bd_c213a30c","line":174,"in_reply_to":"7a016987_98a9e592","updated":"2015-06-01 20:54:21.000000000","message":"Yes, we have implemented this internally. Should I put an example of the cinder.conf in the blueprint itself or just in this reply?\n\nThe key differences is that some of the configuration opts have been separated and remove. I will make an update on the ones that will be removed and why.","commit_id":"4f6e49eeed1f832aad3dddd3021929de7cd98e46"},{"author":{"_account_id":8757,"name":"Angela Smith","email":"angela.smith@broadcom.com","username":"asmith_brcd"},"change_message_id":"42c0884dc724cf2814914890ec4fca0821c68b14","unresolved":false,"context_lines":[{"line_number":20,"context_line":""},{"line_number":21,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":22,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":23,"context_line":"switch types, e.g. switch_type1/switch_type2(Brocade/Cisco) combination."},{"line_number":24,"context_line":""},{"line_number":25,"context_line":"Linear calls down to the zone drivers to perform a zoning operation"},{"line_number":26,"context_line":"limits all switches to use same zone driver."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5afe65bd_3375f897","line":23,"updated":"2015-06-02 22:49:44.000000000","message":"It is not typical for end-users to have both vendor switches in production.  They tend to only have one vendor in all of production fabrics.  This scenario would most likely be seen in testing environments where array and HBA vendors are testing and verifying interoperability of their products with both vendors.","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"},{"author":{"_account_id":5997,"name":"Walt","display_name":"Hemna","email":"waboring@hemna.com","username":"walter-boring","status":"SAP"},"change_message_id":"135d778d0447f8663e92122e9b5e431752acfd60","unresolved":false,"context_lines":[{"line_number":20,"context_line":""},{"line_number":21,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":22,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":23,"context_line":"switch types, e.g. switch_type1/switch_type2(Brocade/Cisco) combination."},{"line_number":24,"context_line":""},{"line_number":25,"context_line":"Linear calls down to the zone drivers to perform a zoning operation"},{"line_number":26,"context_line":"limits all switches to use same zone driver."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5afe65bd_539bd472","line":23,"in_reply_to":"5afe65bd_3375f897","updated":"2015-06-04 15:13:38.000000000","message":"Also, from what I know, you can\u0027t really have a brocade switch in the same fabric as a cisco switch.   I don\u0027t think they play well together managing the same fabric.","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"02a3ad58a1bff2bbe788c92a377a4f8516476394","unresolved":false,"context_lines":[{"line_number":20,"context_line":""},{"line_number":21,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":22,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":23,"context_line":"switch types, e.g. switch_type1/switch_type2(Brocade/Cisco) combination."},{"line_number":24,"context_line":""},{"line_number":25,"context_line":"Linear calls down to the zone drivers to perform a zoning operation"},{"line_number":26,"context_line":"limits all switches to use same zone driver."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5afe65bd_dd9add6d","line":23,"in_reply_to":"5afe65bd_3375f897","updated":"2015-06-04 16:14:56.000000000","message":"We have customers that do this and it is a requirement for them to support switches from multiple vendors in the same environment.","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"02a3ad58a1bff2bbe788c92a377a4f8516476394","unresolved":false,"context_lines":[{"line_number":20,"context_line":""},{"line_number":21,"context_line":"Currently the ZoneManager only allows sequential creation of zones across the"},{"line_number":22,"context_line":"switches for a single type of switch. It cannot zone across multiple unique"},{"line_number":23,"context_line":"switch types, e.g. switch_type1/switch_type2(Brocade/Cisco) combination."},{"line_number":24,"context_line":""},{"line_number":25,"context_line":"Linear calls down to the zone drivers to perform a zoning operation"},{"line_number":26,"context_line":"limits all switches to use same zone driver."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5afe65bd_bd8a8119","line":23,"in_reply_to":"5afe65bd_539bd472","updated":"2015-06-04 16:14:56.000000000","message":"This is not meant to support multiple vendors on the same fabric.  Only redundant fabrics. So the zoning is controlled by a Brocade switch for fabric A. And the zoning is controlled by a Cisco switch for redundant fabric B.","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"},{"author":{"_account_id":12924,"name":"Patrick East","email":"east.patrick@gmail.com","username":"patrick.east"},"change_message_id":"89657b6105c7dcd2009f29e2972aaf5f695aa3a9","unresolved":false,"context_lines":[{"line_number":72,"context_line":"Zone switches in parallel. Zoning the switches concurrently would reduce the"},{"line_number":73,"context_line":"overall time required to create multiple zones. It would also allow different"},{"line_number":74,"context_line":"switch types to be paired. The implementation would remove pluggable"},{"line_number":75,"context_line":"driver architecture and speak directly to the switch\u0027s backend library."},{"line_number":76,"context_line":""},{"line_number":77,"context_line":"The ZoneManger would streamline the initialization of"},{"line_number":78,"context_line":"the fabric CLI clients from the registered fabrics. These CLI connections"}],"source_content_type":"text/x-rst","patch_set":3,"id":"fa32b979_1151880e","line":75,"updated":"2015-06-16 04:04:11.000000000","message":"I\u0027ll have to go stare at the code some more, but I\u0027m not sure I understand why we need to remove the pluggable architecture to do these optimizations. I can get behind the idea of doing these calls faster, in parallel, and to multiple types of switches/zone manager backends, but I really don\u0027t like the idea of stripping out modularity from the existing design if we don\u0027t absolutely have to.","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"},{"author":{"_account_id":15383,"name":"Yucong Feng","email":"yfeng@us.ibm.com","username":"yfeng"},"change_message_id":"2b816184a3e5021882bab34692ab720d4494f656","unresolved":false,"context_lines":[{"line_number":72,"context_line":"Zone switches in parallel. Zoning the switches concurrently would reduce the"},{"line_number":73,"context_line":"overall time required to create multiple zones. It would also allow different"},{"line_number":74,"context_line":"switch types to be paired. The implementation would remove pluggable"},{"line_number":75,"context_line":"driver architecture and speak directly to the switch\u0027s backend library."},{"line_number":76,"context_line":""},{"line_number":77,"context_line":"The ZoneManger would streamline the initialization of"},{"line_number":78,"context_line":"the fabric CLI clients from the registered fabrics. These CLI connections"}],"source_content_type":"text/x-rst","patch_set":3,"id":"fa32b979_157fdfab","line":75,"in_reply_to":"fa32b979_1151880e","updated":"2015-06-17 15:30:33.000000000","message":"It would be more accurate if I had stated that we are making the pluggable architecture more flexible. Current implementation in the cinder configurations sets the \"zone_driver\" to direct specific switch_type driver, which forces all other operations to coincide with only that switch_type driver. This is a very static approach.\n\nWhere as the bp will introduce \"fc_zone_type\" in the fabric configurations, specific to the individual switch_type that would be used. Allowing drivers to be called appropriately for any switch_type configured.\n\nSee line 141, \"Example of zoning configurations for cinder.conf\"","commit_id":"a2267a3c525228fd2195b6e8ecc0492b6bed88b2"}]}