)]}'
{"doc/source/admin/drivers/irmc.rst":[{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. The BIOS"},{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_fd4f848f","line":278,"range":{"start_line":277,"start_character":36,"end_line":278,"end_character":14},"updated":"2017-07-15 13:46:53.000000000","message":"Add clarification that the backup is done only if clean step \u0027restore_irmc_bios_config\u0027 is enabled.","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. The BIOS"},{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_b185a3d1","line":278,"range":{"start_line":277,"start_character":36,"end_line":278,"end_character":14},"in_reply_to":"1f1a1f67_fd4f848f","updated":"2017-07-17 11:07:14.000000000","message":"Done","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. The BIOS"},{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_dd46087d","line":279,"range":{"start_line":279,"start_character":4,"end_line":279,"end_character":11},"updated":"2017-07-15 13:46:53.000000000","message":"s/ \u0027Setting\u0027 / \u0027Set\u0027","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. The BIOS"},{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_916e272d","line":279,"range":{"start_line":279,"start_character":4,"end_line":279,"end_character":11},"in_reply_to":"1f1a1f67_dd46087d","updated":"2017-07-17 11:07:14.000000000","message":"Done","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."},{"line_number":283,"context_line":"  Changing that priority value to 0 will disable the cleaning step and"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_9d609003","line":280,"range":{"start_line":280,"start_character":4,"end_line":280,"end_character":35},"updated":"2017-07-15 13:46:53.000000000","message":"Any reason for this recommended value?","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":277,"context_line":"    settings of a baremetal node is backed up automatically before the"},{"line_number":278,"context_line":"    deployment. By default, this clean step is disabled with priority ``0``."},{"line_number":279,"context_line":"    Setting its priority to a positive integer to enable the clean step."},{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."},{"line_number":283,"context_line":"  Changing that priority value to 0 will disable the cleaning step and"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_55b3da4d","line":280,"range":{"start_line":280,"start_character":4,"end_line":280,"end_character":35},"in_reply_to":"1f1a1f67_9d609003","updated":"2017-07-17 11:07:14.000000000","message":"We plan to use values of 10, 20, 30, 40, ... for priorities and 10 for this clean step. Due to the step quite takes time, so we disable it by default with a recommended value. I think the reason should be transparent to operators.","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."},{"line_number":283,"context_line":"  Changing that priority value to 0 will disable the cleaning step and"},{"line_number":284,"context_line":"  prevent it from execution during automated cleaning. If a positive"},{"line_number":285,"context_line":"  integer is used, the cleaning step will be executed. In order to change"},{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_3d55fc1d","line":283,"range":{"start_line":283,"start_character":34,"end_line":283,"end_character":35},"updated":"2017-07-15 13:46:53.000000000","message":"s/ 0 / ``0`` /","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":280,"context_line":"    The recommended value is ``10``."},{"line_number":281,"context_line":""},{"line_number":282,"context_line":"* Each automated cleaning step has a priority with a default value."},{"line_number":283,"context_line":"  Changing that priority value to 0 will disable the cleaning step and"},{"line_number":284,"context_line":"  prevent it from execution during automated cleaning. If a positive"},{"line_number":285,"context_line":"  integer is used, the cleaning step will be executed. In order to change"},{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_11645749","line":283,"range":{"start_line":283,"start_character":34,"end_line":283,"end_character":35},"in_reply_to":"1f1a1f67_3d55fc1d","updated":"2017-07-17 11:07:14.000000000","message":"Done","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"},{"line_number":287,"context_line":"  updated in ironic.conf."},{"line_number":288,"context_line":""},{"line_number":289,"context_line":"* Configuration Options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_1d324011","line":289,"range":{"start_line":289,"start_character":16,"end_line":289,"end_character":23},"updated":"2017-07-15 13:46:53.000000000","message":"s/ \u0027Options\u0027 / \u0027options\u0027","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"},{"line_number":287,"context_line":"  updated in ironic.conf."},{"line_number":288,"context_line":""},{"line_number":289,"context_line":"* Configuration Options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_31df53d7","line":289,"range":{"start_line":289,"start_character":16,"end_line":289,"end_character":23},"in_reply_to":"1f1a1f67_1d324011","updated":"2017-07-17 11:07:14.000000000","message":"Done","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"a9836402b0c76bc6157bd865c945cc06b0fcf84e","unresolved":false,"context_lines":[{"line_number":289,"context_line":"* Configuration Options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"},{"line_number":293,"context_line":""},{"line_number":294,"context_line":"For more information on node automated cleaning, see :ref:`automated_cleaning`"},{"line_number":295,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_fd3424fd","line":292,"range":{"start_line":292,"start_character":2,"end_line":292,"end_character":3},"updated":"2017-07-15 13:46:53.000000000","message":"s/ \u0027-\u0027 //","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"4d580f84a2213ef4a2db80998f987b16152d1dd6","unresolved":false,"context_lines":[{"line_number":289,"context_line":"* Configuration Options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"},{"line_number":293,"context_line":""},{"line_number":294,"context_line":"For more information on node automated cleaning, see :ref:`automated_cleaning`"},{"line_number":295,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"1f1a1f67_f1f67b63","line":292,"range":{"start_line":292,"start_character":2,"end_line":292,"end_character":3},"in_reply_to":"1f1a1f67_fd3424fd","updated":"2017-07-17 11:07:14.000000000","message":"Done","commit_id":"7749c7c02585d577d00144845977a3005e85f0d4"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"c0602f884bc85c97d6abf90e594ab3ef33fdcca0","unresolved":false,"context_lines":[{"line_number":270,"context_line":"Supported **Automated** Cleaning Operations"},{"line_number":271,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~"},{"line_number":272,"context_line":""},{"line_number":273,"context_line":"* The automated cleaning operations supported are:"},{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. If this"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_bcba71db","line":273,"updated":"2017-07-31 10:36:56.000000000","message":"why do you have a list here? I suggest just leaving everything here as text paragraphs","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"84cafb86fc80d384fff10c97c8dce75115d5ca80","unresolved":false,"context_lines":[{"line_number":270,"context_line":"Supported **Automated** Cleaning Operations"},{"line_number":271,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~"},{"line_number":272,"context_line":""},{"line_number":273,"context_line":"* The automated cleaning operations supported are:"},{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. If this"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_f7dfcbd3","line":273,"in_reply_to":"df3967d1_bcba71db","updated":"2017-08-02 08:17:30.000000000","message":"Done","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"c0602f884bc85c97d6abf90e594ab3ef33fdcca0","unresolved":false,"context_lines":[{"line_number":272,"context_line":""},{"line_number":273,"context_line":"* The automated cleaning operations supported are:"},{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. If this"},{"line_number":277,"context_line":"    clean step is enabled, the BIOS settings of a baremetal node will be"},{"line_number":278,"context_line":"    backed up automatically before the deployment. By default, this clean"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_9ccfad7e","line":275,"updated":"2017-07-31 10:36:56.000000000","message":"and this item can actually be a part of a list (with only one item so far)","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"84cafb86fc80d384fff10c97c8dce75115d5ca80","unresolved":false,"context_lines":[{"line_number":272,"context_line":""},{"line_number":273,"context_line":"* The automated cleaning operations supported are:"},{"line_number":274,"context_line":""},{"line_number":275,"context_line":"  ``restore_irmc_bios_config``:"},{"line_number":276,"context_line":"    Restores BIOS settings on a baremetal node from backup data. If this"},{"line_number":277,"context_line":"    clean step is enabled, the BIOS settings of a baremetal node will be"},{"line_number":278,"context_line":"    backed up automatically before the deployment. By default, this clean"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_b7f38373","line":275,"in_reply_to":"df3967d1_9ccfad7e","updated":"2017-08-02 08:17:30.000000000","message":"Done","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"c0602f884bc85c97d6abf90e594ab3ef33fdcca0","unresolved":false,"context_lines":[{"line_number":284,"context_line":"  prevent it from execution during automated cleaning. If a positive"},{"line_number":285,"context_line":"  integer is used, the cleaning step will be executed. In order to change"},{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"},{"line_number":287,"context_line":"  updated in ironic.conf."},{"line_number":288,"context_line":""},{"line_number":289,"context_line":"* Configuration options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_7ccc0989","line":287,"updated":"2017-07-31 10:36:56.000000000","message":"this duplicates the generic ironic documentation","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"84cafb86fc80d384fff10c97c8dce75115d5ca80","unresolved":false,"context_lines":[{"line_number":284,"context_line":"  prevent it from execution during automated cleaning. If a positive"},{"line_number":285,"context_line":"  integer is used, the cleaning step will be executed. In order to change"},{"line_number":286,"context_line":"  priority of a cleaning step, the respective configuration option must be"},{"line_number":287,"context_line":"  updated in ironic.conf."},{"line_number":288,"context_line":""},{"line_number":289,"context_line":"* Configuration options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_17492fcf","line":287,"in_reply_to":"df3967d1_7ccc0989","updated":"2017-08-02 08:17:30.000000000","message":"Done","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"c0602f884bc85c97d6abf90e594ab3ef33fdcca0","unresolved":false,"context_lines":[{"line_number":289,"context_line":"* Configuration options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"},{"line_number":293,"context_line":""},{"line_number":294,"context_line":"For more information on node automated cleaning, see :ref:`automated_cleaning`"},{"line_number":295,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_5cc94576","line":292,"updated":"2017-07-31 10:36:56.000000000","message":"please remove \"- \" from the beginning, otherwise it\u0027s rendered as part of the example configuration\n\nalso nit: add spaces around \u003d","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"84cafb86fc80d384fff10c97c8dce75115d5ca80","unresolved":false,"context_lines":[{"line_number":289,"context_line":"* Configuration options for the automated cleaning steps are listed under"},{"line_number":290,"context_line":"  ``[irmc]`` section in ironic.conf ::"},{"line_number":291,"context_line":""},{"line_number":292,"context_line":"  - clean_priority_restore_irmc_bios_config\u003d0"},{"line_number":293,"context_line":""},{"line_number":294,"context_line":"For more information on node automated cleaning, see :ref:`automated_cleaning`"},{"line_number":295,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"df3967d1_373af333","line":292,"in_reply_to":"df3967d1_5cc94576","updated":"2017-08-02 08:17:30.000000000","message":"Done","commit_id":"009fdee8ed85b05ba1e480234ce9911ed5fef087"}]}
