{"doc/source/admin/drivers/oneview.rst":[{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"b6f53dc68b13fa6086ee87e449a83b96e88561e1","unresolved":false,"context_lines":[{"line_number":166,"context_line":"*storage* interfaces."},{"line_number":167,"context_line":""},{"line_number":168,"context_line":"To enable the same feature set as provided by all oneview classic drivers,"},{"line_number":169,"context_line":"apply the following configuration:"},{"line_number":170,"context_line":""},{"line_number":171,"context_line":".. code-block:: ini"},{"line_number":172,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_3fd4301f","side":"PARENT","line":169,"updated":"2018-06-29 15:19:02.000000000","message":"We can remove this phrase, but keep the complete example.","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"67a205cf19de609aed0bcfcf33cf0515f4b3f8b5","unresolved":false,"context_lines":[{"line_number":166,"context_line":"*storage* interfaces."},{"line_number":167,"context_line":""},{"line_number":168,"context_line":"To enable the same feature set as provided by all oneview classic drivers,"},{"line_number":169,"context_line":"apply the following configuration:"},{"line_number":170,"context_line":""},{"line_number":171,"context_line":".. code-block:: ini"},{"line_number":172,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_d1af1ede","side":"PARENT","line":169,"in_reply_to":"5f7c97a3_3fd4301f","updated":"2018-07-02 03:57:47.000000000","message":"++","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"d930ed0b4ab50471e31473f70cbb004d2245d1f1","unresolved":false,"context_lines":[{"line_number":166,"context_line":"*storage* interfaces."},{"line_number":167,"context_line":""},{"line_number":168,"context_line":"To enable the same feature set as provided by all oneview classic drivers,"},{"line_number":169,"context_line":"apply the following configuration:"},{"line_number":170,"context_line":""},{"line_number":171,"context_line":".. code-block:: ini"},{"line_number":172,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_113356f9","side":"PARENT","line":169,"in_reply_to":"5f7c97a3_3fd4301f","updated":"2018-07-02 04:03:15.000000000","message":"Done","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"b6f53dc68b13fa6086ee87e449a83b96e88561e1","unresolved":false,"context_lines":[{"line_number":175,"context_line":"    enabled_deploy_interfaces \u003d oneview-direct,oneview-iscsi"},{"line_number":176,"context_line":"    enabled_inspect_interfaces \u003d oneview"},{"line_number":177,"context_line":"    enabled_power_interfaces \u003d oneview"},{"line_number":178,"context_line":"    enabled_management_interfaces \u003d oneview"},{"line_number":179,"context_line":""},{"line_number":180,"context_line":"The following commands can be used to enroll a node with the same"},{"line_number":181,"context_line":"feature set as one of the classic drivers, but using the ``oneview``"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_dfd89c53","side":"PARENT","line":178,"updated":"2018-06-29 15:19:02.000000000","message":"I think we should keep this example","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"d930ed0b4ab50471e31473f70cbb004d2245d1f1","unresolved":false,"context_lines":[{"line_number":175,"context_line":"    enabled_deploy_interfaces \u003d oneview-direct,oneview-iscsi"},{"line_number":176,"context_line":"    enabled_inspect_interfaces \u003d oneview"},{"line_number":177,"context_line":"    enabled_power_interfaces \u003d oneview"},{"line_number":178,"context_line":"    enabled_management_interfaces \u003d oneview"},{"line_number":179,"context_line":""},{"line_number":180,"context_line":"The following commands can be used to enroll a node with the same"},{"line_number":181,"context_line":"feature set as one of the classic drivers, but using the ``oneview``"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_b13142f0","side":"PARENT","line":178,"in_reply_to":"5f7c97a3_dfd89c53","updated":"2018-07-02 04:03:15.000000000","message":"Done","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"b6f53dc68b13fa6086ee87e449a83b96e88561e1","unresolved":false,"context_lines":[{"line_number":201,"context_line":"Hardware inspection"},{"line_number":202,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":203,"context_line":""},{"line_number":204,"context_line":"OneView driver for ironic have the ability to do hardware inspection."},{"line_number":205,"context_line":"Hardware inspection is the process of discovering hardware properties like"},{"line_number":206,"context_line":"memory size, CPU cores, processor architecture and disk size, of a given"},{"line_number":207,"context_line":"hardware. OneView driver does in-band inspection, that involves booting a"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_ffdd5841","line":204,"updated":"2018-06-29 15:19:02.000000000","message":"nit: The OneView driver (or better hardware type)","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"d930ed0b4ab50471e31473f70cbb004d2245d1f1","unresolved":false,"context_lines":[{"line_number":201,"context_line":"Hardware inspection"},{"line_number":202,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":203,"context_line":""},{"line_number":204,"context_line":"OneView driver for ironic have the ability to do hardware inspection."},{"line_number":205,"context_line":"Hardware inspection is the process of discovering hardware properties like"},{"line_number":206,"context_line":"memory size, CPU cores, processor architecture and disk size, of a given"},{"line_number":207,"context_line":"hardware. OneView driver does in-band inspection, that involves booting a"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_71496a64","line":204,"in_reply_to":"5f7c97a3_ffdd5841","updated":"2018-07-02 04:03:15.000000000","message":"The term \"driver\" used in many places, so I keep using it.","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"b6f53dc68b13fa6086ee87e449a83b96e88561e1","unresolved":false,"context_lines":[{"line_number":204,"context_line":"OneView driver for ironic have the ability to do hardware inspection."},{"line_number":205,"context_line":"Hardware inspection is the process of discovering hardware properties like"},{"line_number":206,"context_line":"memory size, CPU cores, processor architecture and disk size, of a given"},{"line_number":207,"context_line":"hardware. OneView driver does in-band inspection, that involves booting a"},{"line_number":208,"context_line":"ramdisk on the hardware and fetching information directly from it. For that,"},{"line_number":209,"context_line":"your cloud controller needs to have the ``ironic-inspector`` component"},{"line_number":210,"context_line":"[9]_ running and properly enabled in ironic\u0027s configuration file."}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_9fe22402","line":207,"updated":"2018-06-29 15:19:02.000000000","message":"ditto","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"d930ed0b4ab50471e31473f70cbb004d2245d1f1","unresolved":false,"context_lines":[{"line_number":204,"context_line":"OneView driver for ironic have the ability to do hardware inspection."},{"line_number":205,"context_line":"Hardware inspection is the process of discovering hardware properties like"},{"line_number":206,"context_line":"memory size, CPU cores, processor architecture and disk size, of a given"},{"line_number":207,"context_line":"hardware. OneView driver does in-band inspection, that involves booting a"},{"line_number":208,"context_line":"ramdisk on the hardware and fetching information directly from it. For that,"},{"line_number":209,"context_line":"your cloud controller needs to have the ``ironic-inspector`` component"},{"line_number":210,"context_line":"[9]_ running and properly enabled in ironic\u0027s configuration file."}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_914c4676","line":207,"in_reply_to":"5f7c97a3_9fe22402","updated":"2018-07-02 04:03:15.000000000","message":"Done","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"b6f53dc68b13fa6086ee87e449a83b96e88561e1","unresolved":false,"context_lines":[{"line_number":215,"context_line":"Registering a OneView node in ironic"},{"line_number":216,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":217,"context_line":""},{"line_number":218,"context_line":"Nodes configured to use any of the OneView driver should have the ``driver``"},{"line_number":219,"context_line":"property set to ``oneview``. Considering our context, a node is the"},{"line_number":220,"context_line":"representation of a ``Server Hardware`` in OneView,"},{"line_number":221,"context_line":"and should be consistent with all its properties and related components, such"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_bfdfe036","line":218,"updated":"2018-06-29 15:19:02.000000000","message":"s/any of//","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"d930ed0b4ab50471e31473f70cbb004d2245d1f1","unresolved":false,"context_lines":[{"line_number":215,"context_line":"Registering a OneView node in ironic"},{"line_number":216,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":217,"context_line":""},{"line_number":218,"context_line":"Nodes configured to use any of the OneView driver should have the ``driver``"},{"line_number":219,"context_line":"property set to ``oneview``. Considering our context, a node is the"},{"line_number":220,"context_line":"representation of a ``Server Hardware`` in OneView,"},{"line_number":221,"context_line":"and should be consistent with all its properties and related components, such"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5f7c97a3_113836c9","line":218,"in_reply_to":"5f7c97a3_bfdfe036","updated":"2018-07-02 04:03:15.000000000","message":"Done","commit_id":"66ecb113e3a01700ba6811eb4303693694b8583d"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"d08b3206c8798c1cbac2ecfc2813f1a0b4ddb25e","unresolved":false,"context_lines":[{"line_number":177,"context_line":"    enabled_power_interfaces \u003d oneview"},{"line_number":178,"context_line":"    enabled_management_interfaces \u003d oneview"},{"line_number":179,"context_line":""},{"line_number":180,"context_line":"The following commands can be used to enroll a node with the same"},{"line_number":181,"context_line":"feature set as one of the classic drivers, but using the ``oneview``"},{"line_number":182,"context_line":"hardware type:"},{"line_number":183,"context_line":""},{"line_number":184,"context_line":"* ``oneview-direct``:"},{"line_number":185,"context_line":""},{"line_number":186,"context_line":"  .. code-block:: console"},{"line_number":187,"context_line":""},{"line_number":188,"context_line":"    openstack baremetal node create --os-baremetal-api-version\u003d1.31 \\"},{"line_number":189,"context_line":"        --driver oneview \\"},{"line_number":190,"context_line":"        --deploy-interface oneview-direct"},{"line_number":191,"context_line":""},{"line_number":192,"context_line":"* ``oneview-iscsi``:"},{"line_number":193,"context_line":""},{"line_number":194,"context_line":"  .. code-block:: console"},{"line_number":195,"context_line":""},{"line_number":196,"context_line":"    openstack baremetal node create --os-baremetal-api-version\u003d1.31 \\"},{"line_number":197,"context_line":"       --driver oneview \\"},{"line_number":198,"context_line":"       --deploy-interface oneview-iscsi"},{"line_number":199,"context_line":""},{"line_number":200,"context_line":"Deploy process with oneview-iscsi deploy interface"}],"source_content_type":"text/x-rst","patch_set":3,"id":"5f7c97a3_343d208e","side":"PARENT","line":197,"range":{"start_line":180,"start_character":0,"end_line":197,"end_character":25},"updated":"2018-07-02 05:49:58.000000000","message":"I think we should retain this example of node creation with as well by removing references to classic drivers.","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"5dfbbbae1ae23558438a58aa56e7945ddbf15ebe","unresolved":false,"context_lines":[{"line_number":177,"context_line":"    enabled_power_interfaces \u003d oneview"},{"line_number":178,"context_line":"    enabled_management_interfaces \u003d oneview"},{"line_number":179,"context_line":""},{"line_number":180,"context_line":"The following commands can be used to enroll a node with the same"},{"line_number":181,"context_line":"feature set as one of the classic drivers, but using the ``oneview``"},{"line_number":182,"context_line":"hardware type:"},{"line_number":183,"context_line":""},{"line_number":184,"context_line":"* ``oneview-direct``:"},{"line_number":185,"context_line":""},{"line_number":186,"context_line":"  .. code-block:: console"},{"line_number":187,"context_line":""},{"line_number":188,"context_line":"    openstack baremetal node create --os-baremetal-api-version\u003d1.31 \\"},{"line_number":189,"context_line":"        --driver oneview \\"},{"line_number":190,"context_line":"        --deploy-interface oneview-direct"},{"line_number":191,"context_line":""},{"line_number":192,"context_line":"* ``oneview-iscsi``:"},{"line_number":193,"context_line":""},{"line_number":194,"context_line":"  .. code-block:: console"},{"line_number":195,"context_line":""},{"line_number":196,"context_line":"    openstack baremetal node create --os-baremetal-api-version\u003d1.31 \\"},{"line_number":197,"context_line":"       --driver oneview \\"},{"line_number":198,"context_line":"       --deploy-interface oneview-iscsi"},{"line_number":199,"context_line":""},{"line_number":200,"context_line":"Deploy process with oneview-iscsi deploy interface"}],"source_content_type":"text/x-rst","patch_set":3,"id":"5f7c97a3_1a6ccbce","side":"PARENT","line":197,"range":{"start_line":180,"start_character":0,"end_line":197,"end_character":25},"in_reply_to":"5f7c97a3_343d208e","updated":"2018-07-02 07:40:07.000000000","message":"I added an equivalent example to the section below.","commit_id":"c45d3c139988aae9cab1ea81061e4a7de81dc2c2"},{"author":{"_account_id":11076,"name":"Shivanand Tendulker","email":"stendulker@gmail.com","username":"stendulker"},"change_message_id":"d08b3206c8798c1cbac2ecfc2813f1a0b4ddb25e","unresolved":false,"context_lines":[{"line_number":165,"context_line":"The ``oneview`` hardware type also supports the standard *network* and"},{"line_number":166,"context_line":"*storage* interfaces."},{"line_number":167,"context_line":""},{"line_number":168,"context_line":"Here is an example of putting multiple interfaces configuration at once."},{"line_number":169,"context_line":""},{"line_number":170,"context_line":".. code-block:: ini"},{"line_number":171,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"5f7c97a3_14a6e40e","line":168,"range":{"start_line":168,"start_character":67,"end_line":168,"end_character":72},"updated":"2018-07-02 05:49:58.000000000","message":"s/ once. / once: /","commit_id":"743142292583a6a8453f264e1bcc8c8b5f24a58c"},{"author":{"_account_id":18320,"name":"Dao Cong Tien","email":"tiendc@vn.fujitsu.com","username":"TienDC"},"change_message_id":"5dfbbbae1ae23558438a58aa56e7945ddbf15ebe","unresolved":false,"context_lines":[{"line_number":165,"context_line":"The ``oneview`` hardware type also supports the standard *network* and"},{"line_number":166,"context_line":"*storage* interfaces."},{"line_number":167,"context_line":""},{"line_number":168,"context_line":"Here is an example of putting multiple interfaces configuration at once."},{"line_number":169,"context_line":""},{"line_number":170,"context_line":".. code-block:: ini"},{"line_number":171,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"5f7c97a3_9a469b50","line":168,"range":{"start_line":168,"start_character":67,"end_line":168,"end_character":72},"in_reply_to":"5f7c97a3_14a6e40e","updated":"2018-07-02 07:40:07.000000000","message":"Done","commit_id":"743142292583a6a8453f264e1bcc8c8b5f24a58c"}]}