{"/COMMIT_MSG":[{"author":{"_account_id":23847,"name":"Richard G. Pioso","email":"richard.pioso@gmail.com","username":"richard.pioso"},"change_message_id":"c920cb229c40a61c17c2b4d465594a911701fc0e","unresolved":false,"context_lines":[{"line_number":7,"context_line":"DRAC: Added redfish management interface issue"},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Added a known issue for the workaround for Continuous mode not being"},{"line_number":10,"context_line":"supported for PXE booting when using the iDRAC redfish management"},{"line_number":11,"context_line":"interface."},{"line_number":12,"context_line":""},{"line_number":13,"context_line":"Change-Id: I082563862e326bc292afc897e7a50dec7d084e9f"}],"source_content_type":"text/x-gerrit-commit-message","patch_set":1,"id":"3f4c43b2_99249ec8","line":10,"range":{"start_line":10,"start_character":14,"end_line":10,"end_character":25},"updated":"2020-04-15 01:44:46.000000000","message":"Does the issue only occur when PXE booting? Perhaps you mean \"setting the boot device\", instead.\n\nAlso, isn\u0027t the issue encountered only when the boot mode is UEFI?","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"},{"author":{"_account_id":10250,"name":"Christopher Dearborn","email":"Christopher.Dearborn@dell.com","username":"cdearbor"},"change_message_id":"76bd4aa7bd57306d8fde54efe856a2c70dcd7ea2","unresolved":false,"context_lines":[{"line_number":7,"context_line":"DRAC: Added redfish management interface issue"},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Added a known issue for the workaround for Continuous mode not being"},{"line_number":10,"context_line":"supported for PXE booting when using the iDRAC redfish management"},{"line_number":11,"context_line":"interface."},{"line_number":12,"context_line":""},{"line_number":13,"context_line":"Change-Id: I082563862e326bc292afc897e7a50dec7d084e9f"}],"source_content_type":"text/x-gerrit-commit-message","patch_set":1,"id":"3f4c43b2_db41ec0d","line":10,"range":{"start_line":10,"start_character":14,"end_line":10,"end_character":25},"in_reply_to":"3f4c43b2_99249ec8","updated":"2020-04-15 18:30:37.000000000","message":"Done","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"}],"doc/source/admin/drivers/idrac.rst":[{"author":{"_account_id":27909,"name":"Aija Jauntēva","email":"code@clusums.eu","username":"ajya"},"change_message_id":"fd949060aa32e9aa984ee60b9b84dbffd899187d","unresolved":false,"context_lines":[{"line_number":591,"context_line":"Redfish management interface failure to set boot device"},{"line_number":592,"context_line":"-------------------------------------------------------"},{"line_number":593,"context_line":""},{"line_number":594,"context_line":"When using the ``idrac-redfish`` management interface with certain iDRAC"},{"line_number":595,"context_line":"firmware versions, the iDRAC will return the following error::"},{"line_number":596,"context_line":""},{"line_number":597,"context_line":"    Unable to Process the request because the value entered for the"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_2d88a4e5","line":594,"range":{"start_line":594,"start_character":59,"end_line":594,"end_character":66},"updated":"2020-04-15 08:39:05.000000000","message":"If these versions are \"certain\", would it be possible to mention which versions exactly?","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"},{"author":{"_account_id":10250,"name":"Christopher Dearborn","email":"Christopher.Dearborn@dell.com","username":"cdearbor"},"change_message_id":"76bd4aa7bd57306d8fde54efe856a2c70dcd7ea2","unresolved":false,"context_lines":[{"line_number":591,"context_line":"Redfish management interface failure to set boot device"},{"line_number":592,"context_line":"-------------------------------------------------------"},{"line_number":593,"context_line":""},{"line_number":594,"context_line":"When using the ``idrac-redfish`` management interface with certain iDRAC"},{"line_number":595,"context_line":"firmware versions, the iDRAC will return the following error::"},{"line_number":596,"context_line":""},{"line_number":597,"context_line":"    Unable to Process the request because the value entered for the"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_3b5f300f","line":594,"range":{"start_line":594,"start_character":59,"end_line":594,"end_character":66},"in_reply_to":"3f4c43b2_2d88a4e5","updated":"2020-04-15 18:30:37.000000000","message":"Done","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"},{"author":{"_account_id":23847,"name":"Richard G. Pioso","email":"richard.pioso@gmail.com","username":"richard.pioso"},"change_message_id":"c920cb229c40a61c17c2b4d465594a911701fc0e","unresolved":false,"context_lines":[{"line_number":591,"context_line":"Redfish management interface failure to set boot device"},{"line_number":592,"context_line":"-------------------------------------------------------"},{"line_number":593,"context_line":""},{"line_number":594,"context_line":"When using the ``idrac-redfish`` management interface with certain iDRAC"},{"line_number":595,"context_line":"firmware versions, the iDRAC will return the following error::"},{"line_number":596,"context_line":""},{"line_number":597,"context_line":"    Unable to Process the request because the value entered for the"},{"line_number":598,"context_line":"    parameter Continuous is not supported by the implementation."},{"line_number":599,"context_line":""},{"line_number":600,"context_line":"To work around this issue, set the ``force_persistent_boot_device`` parameter"},{"line_number":601,"context_line":"in ``driver-info`` on the node to ``Never`` by running the following command"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_fc03100c","line":598,"range":{"start_line":594,"start_character":0,"end_line":598,"end_character":64},"updated":"2020-04-15 01:44:46.000000000","message":"I thought this issue only occurs when the boot mode is set to UEFI on the baremetal. If so, please consider mentioning that.","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"},{"author":{"_account_id":10250,"name":"Christopher Dearborn","email":"Christopher.Dearborn@dell.com","username":"cdearbor"},"change_message_id":"76bd4aa7bd57306d8fde54efe856a2c70dcd7ea2","unresolved":false,"context_lines":[{"line_number":591,"context_line":"Redfish management interface failure to set boot device"},{"line_number":592,"context_line":"-------------------------------------------------------"},{"line_number":593,"context_line":""},{"line_number":594,"context_line":"When using the ``idrac-redfish`` management interface with certain iDRAC"},{"line_number":595,"context_line":"firmware versions, the iDRAC will return the following error::"},{"line_number":596,"context_line":""},{"line_number":597,"context_line":"    Unable to Process the request because the value entered for the"},{"line_number":598,"context_line":"    parameter Continuous is not supported by the implementation."},{"line_number":599,"context_line":""},{"line_number":600,"context_line":"To work around this issue, set the ``force_persistent_boot_device`` parameter"},{"line_number":601,"context_line":"in ``driver-info`` on the node to ``Never`` by running the following command"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_dba56c06","line":598,"range":{"start_line":594,"start_character":0,"end_line":598,"end_character":64},"in_reply_to":"3f4c43b2_fc03100c","updated":"2020-04-15 18:30:37.000000000","message":"Done","commit_id":"caaa8a287d049850c954eb16ee87ca0431c13616"}]}