{"ironic/drivers/modules/drac/bios.py":[{"author":{"_account_id":23847,"name":"Richard G. Pioso","email":"richard.pioso@gmail.com","username":"richard.pioso"},"change_message_id":"377cac299cf461ebc0929d446df2e5f02b825ed0","unresolved":true,"context_lines":[{"line_number":274,"context_line":"            # Calculate difference between current time and factory reset"},{"line_number":275,"context_line":"            # start time if it is more than configured timeout then set"},{"line_number":276,"context_line":"            # the node to fail state"},{"line_number":277,"context_line":"            time \u003d timeutils.utcnow(with_timezone\u003dTrue"},{"line_number":278,"context_line":"                                    ) - timeutils.parse_isotime(str("},{"line_number":279,"context_line":"                                        factory_reset_time))"},{"line_number":280,"context_line":"            time_difference \u003d time.seconds"},{"line_number":281,"context_line":"            LOG.debug(\"Factory resetting node %(node_uuid)s \""},{"line_number":282,"context_line":"                      \"time difference %(time_diffrence)s \","},{"line_number":283,"context_line":"                      {\"node_uuid\": task.node.uuid, \"time_diffrence\":"}],"source_content_type":"text/x-python","patch_set":5,"id":"9f51a4e0_3a867d05","side":"PARENT","line":280,"range":{"start_line":277,"start_character":0,"end_line":280,"end_character":0},"updated":"2021-04-20 01:34:37.000000000","message":"This does seem like a prospective cause of the iDRAC unit test failure which is affecting our gate [1]. However, if my understanding is correct, that test should fail only during a 10 minutes window each day, which represents 0.7% of the time. Is that considered happening quite often?\n\nMight something else be in play here?\n\n[1] https://storage.bhs.cloud.ovh.net/v1/AUTH_dcaab5e32b234d56b626f72581e3644c/zuul_opendev_logs_dd4/786176/4/check/openstack-tox-py38/dd4ce6a/testr_results.html","commit_id":"b4d8a493d9fdb693e64f3d0b11245523c2510665"},{"author":{"_account_id":27909,"name":"Aija Jauntēva","email":"code@clusums.eu","username":"ajya"},"change_message_id":"319c56670941fd63f37ca4c430b604f3fa50ec34","unresolved":true,"context_lines":[{"line_number":274,"context_line":"            # Calculate difference between current time and factory reset"},{"line_number":275,"context_line":"            # start time if it is more than configured timeout then set"},{"line_number":276,"context_line":"            # the node to fail state"},{"line_number":277,"context_line":"            time \u003d timeutils.utcnow(with_timezone\u003dTrue"},{"line_number":278,"context_line":"                                    ) - timeutils.parse_isotime(str("},{"line_number":279,"context_line":"                                        factory_reset_time))"},{"line_number":280,"context_line":"            time_difference \u003d time.seconds"},{"line_number":281,"context_line":"            LOG.debug(\"Factory resetting node %(node_uuid)s \""},{"line_number":282,"context_line":"                      \"time difference %(time_diffrence)s \","},{"line_number":283,"context_line":"                      {\"node_uuid\": task.node.uuid, \"time_diffrence\":"}],"source_content_type":"text/x-python","patch_set":5,"id":"82f1abf0_cc21d260","side":"PARENT","line":280,"range":{"start_line":277,"start_character":0,"end_line":280,"end_character":0},"in_reply_to":"9f51a4e0_3a867d05","updated":"2021-04-20 08:01:41.000000000","message":"I have the same understanding that it is 10 minute window each day when this is failing.\n\nIf want to have cleaner commit, could try to land this patch outside this 10 minute gap and have this fix separately.","commit_id":"b4d8a493d9fdb693e64f3d0b11245523c2510665"}]}