{"doc/source/admin/power-sync.rst":[{"author":{"_account_id":10239,"name":"Dmitry Tantsur","email":"dtantsur@protonmail.com","username":"dtantsur"},"change_message_id":"997865f57877fbc3ffa2b25323ffb0283893b852","unresolved":false,"context_lines":[{"line_number":14,"context_line":"(default: 60 seconds) config option for those nodes which are not in"},{"line_number":15,"context_line":"maintenance. The requests sent to Baseboard Management Controllers (BMCs)"},{"line_number":16,"context_line":"are done with a parallelism controlled by"},{"line_number":17,"context_line":":oslo.config:option:`conductor.sync_power_state_workers` (default: 8 workers)."},{"line_number":18,"context_line":"The motivation to send out requests to BMCs in parallel is to handle"},{"line_number":19,"context_line":"misbehaving BMCs which may delay or even block the synchronization otherwise."},{"line_number":20,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"45aaee07_324a2775","line":17,"updated":"2021-08-19 09:50:13.000000000","message":"Let\u0027s maybe not specify the default? It\u0027s specified in the option documentation, and we\u0027ll forget to update this place if we ever change it.","commit_id":"8c663b8d99fd23b3b502016ad2355a1f1be7590a"}]}