{"neutron/plugins/ml2/drivers/openvswitch/agent/common/constants.py":[{"author":{"_account_id":1653,"name":"garyk","email":"gkotton@vmware.com","username":"garyk"},"change_message_id":"6eaad4b3c09e1cc03622258fbbcd494ba498a454","unresolved":false,"context_lines":[{"line_number":37,"context_line":""},{"line_number":38,"context_line":"### OpenFlow table IDs"},{"line_number":39,"context_line":""},{"line_number":40,"context_line":"## br-int"},{"line_number":41,"context_line":""},{"line_number":42,"context_line":"LOCAL_SWITCHING \u003d 0"},{"line_number":43,"context_line":""}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_ad4c8442","line":40,"updated":"2015-12-13 07:39:44.000000000","message":"what if in my setup this is called br-foo? No idea what this comment actually means","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":6854,"name":"YAMAMOTO Takashi","email":"yamamoto@midokura.com","username":"yamamoto"},"change_message_id":"846a80d9b76ac23495dbed35e453932e0704174f","unresolved":false,"context_lines":[{"line_number":37,"context_line":""},{"line_number":38,"context_line":"### OpenFlow table IDs"},{"line_number":39,"context_line":""},{"line_number":40,"context_line":"## br-int"},{"line_number":41,"context_line":""},{"line_number":42,"context_line":"LOCAL_SWITCHING \u003d 0"},{"line_number":43,"context_line":""}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_ed0e0c3c","line":40,"in_reply_to":"7a740942_ad4c8442","updated":"2015-12-13 09:22:18.000000000","message":"Done","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":1653,"name":"garyk","email":"gkotton@vmware.com","username":"garyk"},"change_message_id":"6eaad4b3c09e1cc03622258fbbcd494ba498a454","unresolved":false,"context_lines":[{"line_number":50,"context_line":"# Table for ARP poison/spoofing prevention rules"},{"line_number":51,"context_line":"ARP_SPOOF_TABLE \u003d 24"},{"line_number":52,"context_line":""},{"line_number":53,"context_line":"## br-tun"},{"line_number":54,"context_line":""},{"line_number":55,"context_line":"# Various tables for tunneling flows"},{"line_number":56,"context_line":"DVR_PROCESS \u003d 1"}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_6d521ce0","line":53,"updated":"2015-12-13 07:39:44.000000000","message":"ditto","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":6854,"name":"YAMAMOTO Takashi","email":"yamamoto@midokura.com","username":"yamamoto"},"change_message_id":"846a80d9b76ac23495dbed35e453932e0704174f","unresolved":false,"context_lines":[{"line_number":50,"context_line":"# Table for ARP poison/spoofing prevention rules"},{"line_number":51,"context_line":"ARP_SPOOF_TABLE \u003d 24"},{"line_number":52,"context_line":""},{"line_number":53,"context_line":"## br-tun"},{"line_number":54,"context_line":""},{"line_number":55,"context_line":"# Various tables for tunneling flows"},{"line_number":56,"context_line":"DVR_PROCESS \u003d 1"}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_0d14b84a","line":53,"in_reply_to":"7a740942_6d521ce0","updated":"2015-12-13 09:22:18.000000000","message":"Done","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":1653,"name":"garyk","email":"gkotton@vmware.com","username":"garyk"},"change_message_id":"6eaad4b3c09e1cc03622258fbbcd494ba498a454","unresolved":false,"context_lines":[{"line_number":65,"context_line":"ARP_RESPONDER \u003d 21"},{"line_number":66,"context_line":"FLOOD_TO_TUN \u003d 22"},{"line_number":67,"context_line":""},{"line_number":68,"context_line":"## br-phys"},{"line_number":69,"context_line":""},{"line_number":70,"context_line":"# Various tables for DVR use of physical bridge flows"},{"line_number":71,"context_line":"DVR_PROCESS_VLAN \u003d 1"}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_8d4f4833","line":68,"updated":"2015-12-13 07:39:44.000000000","message":"ditto","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":6854,"name":"YAMAMOTO Takashi","email":"yamamoto@midokura.com","username":"yamamoto"},"change_message_id":"846a80d9b76ac23495dbed35e453932e0704174f","unresolved":false,"context_lines":[{"line_number":65,"context_line":"ARP_RESPONDER \u003d 21"},{"line_number":66,"context_line":"FLOOD_TO_TUN \u003d 22"},{"line_number":67,"context_line":""},{"line_number":68,"context_line":"## br-phys"},{"line_number":69,"context_line":""},{"line_number":70,"context_line":"# Various tables for DVR use of physical bridge flows"},{"line_number":71,"context_line":"DVR_PROCESS_VLAN \u003d 1"}],"source_content_type":"text/x-python","patch_set":1,"id":"7a740942_ad0d643f","line":68,"in_reply_to":"7a740942_8d4f4833","updated":"2015-12-13 09:22:18.000000000","message":"Done","commit_id":"0cff874b9ba9af28c9bc428787d24f97c9498714"},{"author":{"_account_id":18573,"name":"Petri Kemppainen","email":"petri.kemppainen@nokia.com","username":"petrkemp"},"change_message_id":"f2177fefabd54efdd28caf233f08b642f97f1ddb","unresolved":false,"context_lines":[{"line_number":64,"context_line":"UCAST_TO_TUN \u003d 20"},{"line_number":65,"context_line":"ARP_RESPONDER \u003d 21"},{"line_number":66,"context_line":"FLOOD_TO_TUN \u003d 22"},{"line_number":67,"context_line":""},{"line_number":68,"context_line":"## Physical Bridges (phys_brs)"},{"line_number":69,"context_line":""},{"line_number":70,"context_line":"# Various tables for DVR use of physical bridge flows"}],"source_content_type":"text/x-python","patch_set":2,"id":"7a740942_10b60ff9","line":67,"updated":"2015-12-13 10:00:40.000000000","message":"Bridges --\u003e bridges","commit_id":"a13110c6f970b19a5b816c7af25f5ff16754d8b0"}]}