{"neutron/tests/functional/agent/l3/framework.py":[{"author":{"_account_id":16688,"name":"Rodolfo Alonso","email":"ralonsoh@redhat.com","username":"rodolfo-alonso-hernandez"},"change_message_id":"f4d29bee4266358423c14e61d916c941b5f3d69d","unresolved":false,"context_lines":[{"line_number":275,"context_line":"            interface_name \u003d router.get_external_device_name(port[\u0027id\u0027])"},{"line_number":276,"context_line":"            self._assert_no_ip_addresses_on_interface(router.ns_name,"},{"line_number":277,"context_line":"                                                      interface_name)"},{"line_number":278,"context_line":"            common_utils.wait_until_true(lambda: router.ha_state \u003d\u003d \u0027master\u0027)"},{"line_number":279,"context_line":""},{"line_number":280,"context_line":"            # Keepalived notifies of a state transition when it starts,"},{"line_number":281,"context_line":"            # not when it ends. Thus, we have to wait until keepalived finishes"}],"source_content_type":"text/x-python","patch_set":1,"id":"9fdfeff1_a45f050d","side":"PARENT","line":278,"updated":"2019-03-01 15:33:50.000000000","message":"Please, correct me if I\u0027m wrong. According to the bug description, you state that at this point (sometimes), the router has already transitioned to master. That means the removed section is irrelevant (or is going to fail).","commit_id":"7fbba811edec6093df07f615358e90c8acac68a5"},{"author":{"_account_id":11975,"name":"Slawek Kaplonski","email":"skaplons@redhat.com","username":"slaweq"},"change_message_id":"5a06a40cfa5d318135622a5d81e1a6118ac86665","unresolved":false,"context_lines":[{"line_number":275,"context_line":"            interface_name \u003d router.get_external_device_name(port[\u0027id\u0027])"},{"line_number":276,"context_line":"            self._assert_no_ip_addresses_on_interface(router.ns_name,"},{"line_number":277,"context_line":"                                                      interface_name)"},{"line_number":278,"context_line":"            common_utils.wait_until_true(lambda: router.ha_state \u003d\u003d \u0027master\u0027)"},{"line_number":279,"context_line":""},{"line_number":280,"context_line":"            # Keepalived notifies of a state transition when it starts,"},{"line_number":281,"context_line":"            # not when it ends. Thus, we have to wait until keepalived finishes"}],"source_content_type":"text/x-python","patch_set":1,"id":"9fdfeff1_049371a4","side":"PARENT","line":278,"in_reply_to":"9fdfeff1_a45f050d","updated":"2019-03-01 15:37:13.000000000","message":"yes, exactly that happens sometimes. When test went to this assert in L276, router was already transitioned to master and IPs were configured so test failed.","commit_id":"7fbba811edec6093df07f615358e90c8acac68a5"}]}