{"doc/source/admin/ovn/igmp.rst":[{"author":{"_account_id":23804,"name":"Daniel Alvarez","email":"dalvarez@redhat.com","username":"dalvarez"},"change_message_id":"316ffd3e6be3b9ac2e01f937b3fbd7d4ae40f8a2","unresolved":false,"context_lines":[{"line_number":66,"context_line":""},{"line_number":67,"context_line":".. note::"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"   Since IGMP querier is not yet supported in the OVN driver, restaring"},{"line_number":70,"context_line":"   the ovn-controller service(s) will result in OVN unlearning the"},{"line_number":71,"context_line":"   IGMP groups."},{"line_number":72,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_c79491eb","line":69,"range":{"start_line":69,"start_character":62,"end_line":69,"end_character":71},"updated":"2020-04-14 12:35:00.000000000","message":"restarting","commit_id":"6505d1865a837c0a0773b1475a4f09f03714a454"},{"author":{"_account_id":6773,"name":"Lucas Alvares Gomes","email":"lucasagomes@gmail.com","username":"lucasagomes"},"change_message_id":"8a742905fef81b6c978986da6749564a9e73194e","unresolved":false,"context_lines":[{"line_number":66,"context_line":""},{"line_number":67,"context_line":".. note::"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"   Since IGMP querier is not yet supported in the OVN driver, restaring"},{"line_number":70,"context_line":"   the ovn-controller service(s) will result in OVN unlearning the"},{"line_number":71,"context_line":"   IGMP groups."},{"line_number":72,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_87aba91b","line":69,"range":{"start_line":69,"start_character":62,"end_line":69,"end_character":71},"in_reply_to":"3f4c43b2_c79491eb","updated":"2020-04-14 12:47:30.000000000","message":"T.T","commit_id":"6505d1865a837c0a0773b1475a4f09f03714a454"},{"author":{"_account_id":23804,"name":"Daniel Alvarez","email":"dalvarez@redhat.com","username":"dalvarez"},"change_message_id":"316ffd3e6be3b9ac2e01f937b3fbd7d4ae40f8a2","unresolved":false,"context_lines":[{"line_number":68,"context_line":""},{"line_number":69,"context_line":"   Since IGMP querier is not yet supported in the OVN driver, restaring"},{"line_number":70,"context_line":"   the ovn-controller service(s) will result in OVN unlearning the"},{"line_number":71,"context_line":"   IGMP groups."},{"line_number":72,"context_line":""},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"Extra information"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_879289f5","line":71,"range":{"start_line":71,"start_character":14,"end_line":71,"end_character":15},"updated":"2020-04-14 12:35:00.000000000","message":"and broadcasting all the multicast traffic.\n\nHave you checked disconnections? I think disconnections would be safe but worth mentioning it / testing it out","commit_id":"6505d1865a837c0a0773b1475a4f09f03714a454"},{"author":{"_account_id":6773,"name":"Lucas Alvares Gomes","email":"lucasagomes@gmail.com","username":"lucasagomes"},"change_message_id":"8a742905fef81b6c978986da6749564a9e73194e","unresolved":false,"context_lines":[{"line_number":68,"context_line":""},{"line_number":69,"context_line":"   Since IGMP querier is not yet supported in the OVN driver, restaring"},{"line_number":70,"context_line":"   the ovn-controller service(s) will result in OVN unlearning the"},{"line_number":71,"context_line":"   IGMP groups."},{"line_number":72,"context_line":""},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"Extra information"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_475fe140","line":71,"range":{"start_line":71,"start_character":14,"end_line":71,"end_character":15},"in_reply_to":"3f4c43b2_879289f5","updated":"2020-04-14 12:47:30.000000000","message":"Done...\n\nI tested the re-connections by killing the connection from ovn controller with the OVSDB SBDB [0], nothing happens with the IGMP groups.\n\n[0] sudo ss -K dst 192.168.1.5 dport \u003d 6642\n\nThe logs:\n\n2020-04-14T12:41:23.610Z|00052|reconnect|INFO|tcp:192.168.1.5:6642: connecting...\n2020-04-14T12:41:23.610Z|00053|reconnect|INFO|tcp:192.168.1.5:6642: connected","commit_id":"6505d1865a837c0a0773b1475a4f09f03714a454"},{"author":{"_account_id":23804,"name":"Daniel Alvarez","email":"dalvarez@redhat.com","username":"dalvarez"},"change_message_id":"46a201550db05b901756e9f400863f60d872934f","unresolved":false,"context_lines":[{"line_number":68,"context_line":""},{"line_number":69,"context_line":"   Since IGMP querier is not yet supported in the OVN driver, restaring"},{"line_number":70,"context_line":"   the ovn-controller service(s) will result in OVN unlearning the"},{"line_number":71,"context_line":"   IGMP groups."},{"line_number":72,"context_line":""},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"Extra information"}],"source_content_type":"text/x-rst","patch_set":1,"id":"3f4c43b2_4adc0874","line":71,"range":{"start_line":71,"start_character":14,"end_line":71,"end_character":15},"in_reply_to":"3f4c43b2_879289f5","updated":"2020-04-14 12:47:40.000000000","message":"This has an update/upgrade impact as if ovn-controller is updated, then the multicast traffic will be automatically broadcasted.\n\nI believe this is the same thing with ML2/OVS in the case that OVS is restarted as I don\u0027t think querier is at all supported in OVS.\n\nWorth noting the update/upgrade impact, what do you think?","commit_id":"6505d1865a837c0a0773b1475a4f09f03714a454"}]}