{"/PATCHSET_LEVEL":[{"author":{"_account_id":23567,"name":"Luis Tomas Bolivar","email":"ltomasbo@redhat.com","username":"ltomasbo"},"change_message_id":"c3686f99f5ecf654c070657e2a64f3e4e06b6185","unresolved":false,"context_lines":[],"source_content_type":"","patch_set":2,"id":"e511ff3b_097c007d","updated":"2022-03-15 08:46:46.000000000","message":"other than the pep8 (extra import) leftover, it looks good to me","commit_id":"ed8e0400ba3aa8e5ccd6364bc2562a4f135a2407"},{"author":{"_account_id":6773,"name":"Lucas Alvares Gomes","email":"lucasagomes@gmail.com","username":"lucasagomes"},"change_message_id":"0c645082f1b8551dac5470ff997042c5f6c87e42","unresolved":false,"context_lines":[],"source_content_type":"","patch_set":3,"id":"6093c81a_14e88fc0","updated":"2022-03-15 10:16:27.000000000","message":"I need to look more into it but, I don\u0027t think we should remove this task method because, even tho the Logical Switches are created or updated accordingly with the IGMP configuration option this maintenance task still covers the case where the configuration option value is changed and the Neutron service is restarted without any updates to the Logical Switches. In this case this maintenance task will pick up on the new values of the IGMP configuration option and configure the LS accordingly ","commit_id":"8c92e4d4806c7070bc14a0d554b87334d45e48c4"}]}