)]}'
{"/COMMIT_MSG":[{"author":{"_account_id":8313,"name":"Lajos Katona","display_name":"lajoskatona","email":"katonalala@gmail.com","username":"elajkat","status":"Ericsson Software Technology"},"change_message_id":"92e769673f66164f05c104c633f3ced520442426","unresolved":true,"context_lines":[{"line_number":4,"context_line":"Commit:     renliang17 \u003crenliang@uniontech.com\u003e"},{"line_number":5,"context_line":"CommitDate: 2022-07-07 15:09:11 +0800"},{"line_number":6,"context_line":""},{"line_number":7,"context_line":"Updated information about the Mellanox SR-IOV Ethernet ConnectX card."},{"line_number":8,"context_line":"Demoved information about the Broadcom NetxTreme-E series Ethernet card."},{"line_number":9,"context_line":""},{"line_number":10,"context_line":"Ethernet card information about the Mellanox series, https://www.nvidia.com/en-us/support/enterprise has replaced the new address."},{"line_number":11,"context_line":""}],"source_content_type":"text/x-gerrit-commit-message","patch_set":1,"id":"b00d1c80_4b8a3e2e","line":8,"range":{"start_line":7,"start_character":0,"end_line":8,"end_character":72},"updated":"2022-07-11 10:13:03.000000000","message":"please have only one line of header with short summary.","commit_id":"31d8a99733972ec594c63a5a34bffdfcb844ebb6"},{"author":{"_account_id":8313,"name":"Lajos Katona","display_name":"lajoskatona","email":"katonalala@gmail.com","username":"elajkat","status":"Ericsson Software Technology"},"change_message_id":"92e769673f66164f05c104c633f3ced520442426","unresolved":true,"context_lines":[{"line_number":6,"context_line":""},{"line_number":7,"context_line":"Updated information about the Mellanox SR-IOV Ethernet ConnectX card."},{"line_number":8,"context_line":"Demoved information about the Broadcom NetxTreme-E series Ethernet card."},{"line_number":9,"context_line":""},{"line_number":10,"context_line":"Ethernet card information about the Mellanox series, https://www.nvidia.com/en-us/support/enterprise has replaced the new address."},{"line_number":11,"context_line":""},{"line_number":12,"context_line":"Better information about the Broadcom NetXtrem Ethernet card was not found, so the information about the Broadcom Ethernet card was removed."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Change-Id: I077c686310638081198acea81e8a26bcbd5cd934"}],"source_content_type":"text/x-gerrit-commit-message","patch_set":1,"id":"d37186ec_1ec8a250","line":12,"range":{"start_line":9,"start_character":0,"end_line":12,"end_character":140},"updated":"2022-07-11 10:13:03.000000000","message":"please break the lines to less than 80 chars, links can be longer of course, but try to have them in a new line","commit_id":"31d8a99733972ec594c63a5a34bffdfcb844ebb6"}],"/PATCHSET_LEVEL":[{"author":{"_account_id":8313,"name":"Lajos Katona","display_name":"lajoskatona","email":"katonalala@gmail.com","username":"elajkat","status":"Ericsson Software Technology"},"change_message_id":"92e769673f66164f05c104c633f3ced520442426","unresolved":false,"context_lines":[],"source_content_type":"","patch_set":1,"id":"2e1cf494_a69e091b","updated":"2022-07-11 10:13:03.000000000","message":"thanks for taking care, please check my formatting comments","commit_id":"31d8a99733972ec594c63a5a34bffdfcb844ebb6"}],"doc/source/admin/config-sriov.rst":[{"author":{"_account_id":34271,"name":"Miro Tomaska","display_name":"Miro Tomaska","email":"mtomaska@redhat.com","username":"mtomaska"},"change_message_id":"9b7da4aff9bcb1064f1d58b5a7136d0ec891af41","unresolved":true,"context_lines":[{"line_number":59,"context_line":""},{"line_number":60,"context_line":"The following manufacturers are known to work:"},{"line_number":61,"context_line":""},{"line_number":62,"context_line":"- Intel"},{"line_number":63,"context_line":"- Mellanox"},{"line_number":64,"context_line":"- QLogic"},{"line_number":65,"context_line":"- Broadcom"},{"line_number":66,"context_line":""},{"line_number":67,"context_line":"For information on **Mellanox SR-IOV Ethernet ConnectX cards**, see:"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-4 or newer \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx4/cx5sr-iovconfigConfiguringSR-IOVforConnectX-4/ConnectX-5(Ethernet)\u003e`_."},{"line_number":70,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-3/ConnectX-3 Pro \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx-3/prosr-iovconfigConfiguringSR-IOVforConnectX-3/ConnectX-3Pro\u003e`_."},{"line_number":71,"context_line":""},{"line_number":72,"context_line":"For information on **QLogic SR-IOV Ethernet cards**, see:"},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"- `User\u0027s Guide OpenStack Deployment with SR-IOV Configuration \u003chttp://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf\u003e`_."},{"line_number":75,"context_line":""},{"line_number":76,"context_line":"Using SR-IOV interfaces"},{"line_number":77,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~"},{"line_number":78,"context_line":""},{"line_number":79,"context_line":"In order to enable SR-IOV, the following steps are required:"}],"source_content_type":"text/x-rst","patch_set":3,"id":"26e3869b_1ddfad8c","line":76,"range":{"start_line":62,"start_character":0,"end_line":76,"end_character":0},"updated":"2022-07-12 19:30:47.000000000","message":"Just my thoughts to consider:\nLooks like its common for these things to go stale. In addition, we do not list help documents for all the manufactures we list(missing Intel, now you removing Broadcom). I am wondering if we should make our verbiage more general:\n\n\"Refer to manufactures support documentation for most up to date information. For example, Mellanos SR-IOV Ethernet ConnectX cards, see: \u003clinks\u003e\"\nThis way its more of a \"best effort\" on our end but we are giving the reader next steps where to look for this information.","commit_id":"17a5aef6cf3763e86ea2726482e39b1dc052a1de"},{"author":{"_account_id":11975,"name":"Slawek Kaplonski","email":"skaplons@redhat.com","username":"slaweq"},"change_message_id":"f0800c6dfe0ec91fda50af076357d84f41fc2697","unresolved":true,"context_lines":[{"line_number":59,"context_line":""},{"line_number":60,"context_line":"The following manufacturers are known to work:"},{"line_number":61,"context_line":""},{"line_number":62,"context_line":"- Intel"},{"line_number":63,"context_line":"- Mellanox"},{"line_number":64,"context_line":"- QLogic"},{"line_number":65,"context_line":"- Broadcom"},{"line_number":66,"context_line":""},{"line_number":67,"context_line":"For information on **Mellanox SR-IOV Ethernet ConnectX cards**, see:"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-4 or newer \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx4/cx5sr-iovconfigConfiguringSR-IOVforConnectX-4/ConnectX-5(Ethernet)\u003e`_."},{"line_number":70,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-3/ConnectX-3 Pro \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx-3/prosr-iovconfigConfiguringSR-IOVforConnectX-3/ConnectX-3Pro\u003e`_."},{"line_number":71,"context_line":""},{"line_number":72,"context_line":"For information on **QLogic SR-IOV Ethernet cards**, see:"},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"- `User\u0027s Guide OpenStack Deployment with SR-IOV Configuration \u003chttp://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf\u003e`_."},{"line_number":75,"context_line":""},{"line_number":76,"context_line":"Using SR-IOV interfaces"},{"line_number":77,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~"},{"line_number":78,"context_line":""},{"line_number":79,"context_line":"In order to enable SR-IOV, the following steps are required:"}],"source_content_type":"text/x-rst","patch_set":3,"id":"ea9bb43e_39ad5ca0","line":76,"range":{"start_line":62,"start_character":0,"end_line":76,"end_character":0},"in_reply_to":"26e3869b_1ddfad8c","updated":"2022-07-18 10:58:17.000000000","message":"+1. I like the idea of making it more \"generic\" and best effort thing in our docs","commit_id":"17a5aef6cf3763e86ea2726482e39b1dc052a1de"},{"author":{"_account_id":8313,"name":"Lajos Katona","display_name":"lajoskatona","email":"katonalala@gmail.com","username":"elajkat","status":"Ericsson Software Technology"},"change_message_id":"7dca2f29782b8767de7defa103f3ad74ecba90b0","unresolved":true,"context_lines":[{"line_number":59,"context_line":""},{"line_number":60,"context_line":"The following manufacturers are known to work:"},{"line_number":61,"context_line":""},{"line_number":62,"context_line":"- Intel"},{"line_number":63,"context_line":"- Mellanox"},{"line_number":64,"context_line":"- QLogic"},{"line_number":65,"context_line":"- Broadcom"},{"line_number":66,"context_line":""},{"line_number":67,"context_line":"For information on **Mellanox SR-IOV Ethernet ConnectX cards**, see:"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-4 or newer \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx4/cx5sr-iovconfigConfiguringSR-IOVforConnectX-4/ConnectX-5(Ethernet)\u003e`_."},{"line_number":70,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-3/ConnectX-3 Pro \u003chttps://docs.nvidia.com/networking/pages/viewpage.action?pageId\u003d12005023#SingleRootIOVirtualization(SRIOV)-cx-3/prosr-iovconfigConfiguringSR-IOVforConnectX-3/ConnectX-3Pro\u003e`_."},{"line_number":71,"context_line":""},{"line_number":72,"context_line":"For information on **QLogic SR-IOV Ethernet cards**, see:"},{"line_number":73,"context_line":""},{"line_number":74,"context_line":"- `User\u0027s Guide OpenStack Deployment with SR-IOV Configuration \u003chttp://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf\u003e`_."},{"line_number":75,"context_line":""},{"line_number":76,"context_line":"Using SR-IOV interfaces"},{"line_number":77,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~"},{"line_number":78,"context_line":""},{"line_number":79,"context_line":"In order to enable SR-IOV, the following steps are required:"}],"source_content_type":"text/x-rst","patch_set":3,"id":"4f354800_6af48983","line":76,"range":{"start_line":62,"start_character":0,"end_line":76,"end_character":0},"in_reply_to":"ea9bb43e_39ad5ca0","updated":"2022-07-22 07:32:08.000000000","message":"+1, good idea","commit_id":"17a5aef6cf3763e86ea2726482e39b1dc052a1de"},{"author":{"_account_id":16688,"name":"Rodolfo Alonso","email":"ralonsoh@redhat.com","username":"rodolfo-alonso-hernandez"},"change_message_id":"a91cdc147cab570a88beeab333dfcd34c71c522f","unresolved":true,"context_lines":[{"line_number":66,"context_line":""},{"line_number":67,"context_line":"For information on **Mellanox SR-IOV Ethernet ConnectX cards**, see:"},{"line_number":68,"context_line":""},{"line_number":69,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-4 or newer \u003chttps://community.mellanox.com/s/article/HowTo-Configure-SR-IOV-for-ConnectX-4-ConnectX-5-ConnectX-6-with-KVM-Ethernet\u003e`_."},{"line_number":70,"context_line":"- `Mellanox: How To Configure SR-IOV VFs on ConnectX-3/ConnectX-3 Pro \u003chttps://community.mellanox.com/docs/DOC-1484\u003e`_."},{"line_number":71,"context_line":""},{"line_number":72,"context_line":"For information on **QLogic SR-IOV Ethernet cards**, see:"}],"source_content_type":"text/x-rst","patch_set":4,"id":"97c73761_872c764f","side":"PARENT","line":69,"range":{"start_line":69,"start_character":65,"end_line":69,"end_character":183},"updated":"2022-07-13 11:14:29.000000000","message":"There is an updated link to this document: https://support.mellanox.com/s/article/HowTo-Configure-SR-IOV-for-ConnectX-4-ConnectX-5-ConnectX-6-with-KVM-Ethernet\n\nI think it is relevant to keep it.","commit_id":"ac0f24735205612922be90e41c911056faf8ac14"},{"author":{"_account_id":16688,"name":"Rodolfo Alonso","email":"ralonsoh@redhat.com","username":"rodolfo-alonso-hernandez"},"change_message_id":"a91cdc147cab570a88beeab333dfcd34c71c522f","unresolved":true,"context_lines":[{"line_number":71,"context_line":"- `User\u0027s Guide OpenStack Deployment with SR-IOV Configuration \u003chttp://www.qlogic.com/solutions/Documents/UsersGuide_OpenStack_SR-IOV.pdf\u003e`_."},{"line_number":72,"context_line":""},{"line_number":73,"context_line":"For information on **Broadcom NetXtreme Series Ethernet cards**, see the"},{"line_number":74,"context_line":"`Broadcom NetXtreme Product Page \u003chttps://www.broadcom.com/products\u003e`_."},{"line_number":75,"context_line":""},{"line_number":76,"context_line":"Using SR-IOV interfaces"},{"line_number":77,"context_line":"~~~~~~~~~~~~~~~~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":4,"id":"06a273ab_83a28a60","line":74,"range":{"start_line":74,"start_character":34,"end_line":74,"end_character":67},"updated":"2022-07-13 11:14:29.000000000","message":"This is https://www.broadcom.com/products/ethernet-connectivity/network-adapters","commit_id":"3901ee0888e569a571eb7f8cd3486a9ef544f76f"}]}
