{"specs/train/approved/nova-llc-allocation-rmd-plugin-for-rdt-cat.rst":[{"author":{"_account_id":26458,"name":"Brin Zhang","email":"zhangbailin@inspur.com","username":"zhangbailin"},"change_message_id":"35063bf8f8b06b10d479042fac51c3afc13749f5","unresolved":false,"context_lines":[{"line_number":384,"context_line":""},{"line_number":385,"context_line":"  ii. In order to avoid conversion approximation while converting MB to LLC"},{"line_number":386,"context_line":"      way units, we expect the user to request LLC MB values as multiples of"},{"line_number":387,"context_line":"\t  size of one LLC way in MB"},{"line_number":388,"context_line":""},{"line_number":389,"context_line":"   * E.g. If 1 LLC way \u003d 2 MB, for the workload to land on such a compute"},{"line_number":390,"context_line":"     node, the user must request LLC in multiples of 2 MB, so that 2 MB"}],"source_content_type":"text/x-rst","patch_set":2,"id":"5fc1f717_5dc6559c","line":387,"range":{"start_line":387,"start_character":0,"end_line":387,"end_character":1},"updated":"2019-04-10 10:30:16.000000000","message":"Unexpected indentation, so the zuul test failed.","commit_id":"362ea2237bf67a047ba77853ecb98675572e3696"}]}