{"/COMMIT_MSG":[{"author":{"_account_id":538,"name":"Major Hayden","email":"major@mhtx.net","username":"rackerhacker"},"change_message_id":"77e75f5367223fc4f973e03e9b9ce2da0ba94479","unresolved":false,"context_lines":[{"line_number":9,"context_line":"The max connection calculation uses the number of vcpus reported by ansible"},{"line_number":10,"context_line":"however it\u0027s using the wrong value in one portion of the calculation. The"},{"line_number":11,"context_line":"result is that the calculation returns 0 rather than the intended 200 when"},{"line_number":12,"context_line":"there are both x87 and POWER controllers."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Change-Id: I48314a3b701da4df6aaa0c163b14da36a1e70b7f"},{"line_number":15,"context_line":"Closes-Bug: #1647106"}],"source_content_type":"text/x-gerrit-commit-message","patch_set":2,"id":"3a71b18c_6cd5861a","line":12,"updated":"2016-12-05 15:20:27.000000000","message":"Nit: s/x87/x86/","commit_id":"402d70b0ca556685383ead3ec6ffe1f3a8e8d31c"}]}