)]}'
{"doc/config-reference/source/block-storage/drivers/nexentastor5-driver.rst":[{"author":{"_account_id":6547,"name":"Andreas Jaeger","email":"jaegerandi@gmail.com","username":"jaegerandi"},"change_message_id":"a80c93da9b3807f204df1caa5e242b11fb598da3","unresolved":false,"context_lines":[{"line_number":1,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":2,"context_line":"NexentaStor 5.x NFS and iSCSI Drivers"},{"line_number":3,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":4,"context_line":""},{"line_number":5,"context_line":"NexentaStor is an Open Source-driven Software-Defined Storage (OpenSDS)"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_37370be5","line":2,"range":{"start_line":2,"start_character":30,"end_line":2,"end_character":36},"updated":"2016-04-12 06:02:56.000000000","message":"sentence style caps for all titles, also below. The current version is correct","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":4,"context_line":""},{"line_number":5,"context_line":"NexentaStor is an Open Source-driven Software-Defined Storage (OpenSDS)"},{"line_number":6,"context_line":"platform delivering unified file (NFS and SMB) and block (FC and iSCSI)"},{"line_number":7,"context_line":"storage services, runs on industry standard hardware, scales from tens"},{"line_number":8,"context_line":"of terabytes to petabyte configurations, and includes all data management"},{"line_number":9,"context_line":"functionality by default."},{"line_number":10,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_ca254faf","line":7,"updated":"2016-04-12 02:10:34.000000000","message":"Switch the comma to a full stop here - \u0027 ..and block (FC and iSCSI) storage services. NexentaStor runs industry standard hardware.. \u0027","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":8,"context_line":"of terabytes to petabyte configurations, and includes all data management"},{"line_number":9,"context_line":"functionality by default."},{"line_number":10,"context_line":""},{"line_number":11,"context_line":"NexentaStor 5 brings some new features to the table, such as:"},{"line_number":12,"context_line":""},{"line_number":13,"context_line":"* Installation"},{"line_number":14,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_8a34f7de","line":11,"updated":"2016-04-12 02:10:34.000000000","message":"Switch the word choice here. The sentence reads slightly too conversational - \u0027 NexentaStor 5 includes several new features: \u0027","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":6547,"name":"Andreas Jaeger","email":"jaegerandi@gmail.com","username":"jaegerandi"},"change_message_id":"a80c93da9b3807f204df1caa5e242b11fb598da3","unresolved":false,"context_lines":[{"line_number":8,"context_line":"of terabytes to petabyte configurations, and includes all data management"},{"line_number":9,"context_line":"functionality by default."},{"line_number":10,"context_line":""},{"line_number":11,"context_line":"NexentaStor 5 brings some new features to the table, such as:"},{"line_number":12,"context_line":""},{"line_number":13,"context_line":"* Installation"},{"line_number":14,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_b7515b11","line":11,"in_reply_to":"5a18252c_8a34f7de","updated":"2016-04-12 06:02:56.000000000","message":"This is not a marketing document, please restrict yourself to what is beneficial for OpenStack and link to other documents if needed.","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":26,"context_line":""},{"line_number":27,"context_line":"   * Performance monitoring in summary and component dashboards"},{"line_number":28,"context_line":""},{"line_number":29,"context_line":"   * High-Availability(HA) Cluster displayed as a single appliance"},{"line_number":30,"context_line":""},{"line_number":31,"context_line":"   * Multi-appliance management"},{"line_number":32,"context_line":""}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_aa51f310","line":29,"updated":"2016-04-12 02:10:34.000000000","message":"Add a space here - \u0027 High-Availability (HA) \u0027","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":52,"context_line":""},{"line_number":53,"context_line":"   * VVOL Support to manage storage policies"},{"line_number":54,"context_line":""},{"line_number":55,"context_line":"For NexentaStor user documentation, please visit http://docs.nexenta.com/"},{"line_number":56,"context_line":""},{"line_number":57,"context_line":"Supported Operations"},{"line_number":58,"context_line":"~~~~~~~~~~~~~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_6ab6bb3e","line":55,"updated":"2016-04-12 02:10:34.000000000","message":"Use url link formatting when referencing external urls - http://docs.openstack.org/contributor-guide/rst-conv/refs.html","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":77,"context_line":""},{"line_number":78,"context_line":"iSCSI driver"},{"line_number":79,"context_line":"~~~~~~~~~~~~~~~~~~~~"},{"line_number":80,"context_line":""},{"line_number":81,"context_line":"The NexentaStor appliance must be installed and configured according to the"},{"line_number":82,"context_line":"relevant Nexenta documentation. A pool and an enclosing namespace must be"},{"line_number":83,"context_line":"created for all iSCSI volumes to be accessed through the volume driver. This"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_4a965f95","line":80,"updated":"2016-04-12 02:10:34.000000000","message":"It\u0027s okay to have the ~ marker match the title length. No need for consistent length throughout the document.\n\niSCSI driver\n~~~~~~~~~~~~\n\n^this is fine.","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":127,"context_line":"   restart the ``cinder-volume`` service."},{"line_number":128,"context_line":""},{"line_number":129,"context_line":"NFS Driver"},{"line_number":130,"context_line":"~~~~~~~~~~~~~~~~~~~~"},{"line_number":131,"context_line":"The Nexenta NFS driver allows you to use NexentaStor appliance to store"},{"line_number":132,"context_line":"Compute volumes via NFS. Every Compute volume is represented by a single"},{"line_number":133,"context_line":"NFS file within a shared directory."}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_8a907797","line":130,"updated":"2016-04-12 02:10:34.000000000","message":"As on line 80, ~ use matches the title length.","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a95986471c59fcf98da87a8d67797e7595de0cc0","unresolved":false,"context_lines":[{"line_number":141,"context_line":"The NexentaStor appliance must be installed and configured according to the"},{"line_number":142,"context_line":"relevant Nexenta documentation. A single-parent file system must be created"},{"line_number":143,"context_line":"for all virtual disk directories supported for OpenStack. This directory must"},{"line_number":144,"context_line":"be created and exported on each NexentaStor appliance."},{"line_number":145,"context_line":""},{"line_number":146,"context_line":"For more information on NexentaStor configuration and specs, please visit"},{"line_number":147,"context_line":"http://docs.nexenta.com/"}],"source_content_type":"text/x-rst","patch_set":1,"id":"5a18252c_0af3c70b","line":144,"updated":"2016-04-12 02:10:34.000000000","message":"Switch to active voice here -\n\u0027 Create and export the directory on each NexentaStor appliance. \u0027","commit_id":"c3f24aaf1886fcb0d861d3118e74777ec5a6b9fd"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"a0ab3fae102d43290b4c47ea87d4b8150b841feb","unresolved":false,"context_lines":[{"line_number":3,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":4,"context_line":""},{"line_number":5,"context_line":"NexentaStor is an Open Source-driven Software-Defined Storage (OpenSDS)"},{"line_number":6,"context_line":"platform delivering unified file (NFS and SMB) and block (FC and iSCSI)"},{"line_number":7,"context_line":"storage services. NexentaStor runs on industry standard hardware, scales from"},{"line_number":8,"context_line":"tens of terabytes to petabyte configurations, and includes all data management"},{"line_number":9,"context_line":"functionality by default."}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_f161e8a9","line":6,"range":{"start_line":6,"start_character":52,"end_line":6,"end_character":57},"updated":"2016-04-13 04:10:20.000000000","message":"Block Storage*","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":15439,"name":"Alexey Khodos","email":"akhodos@ddn.com","username":"Alexey"},"change_message_id":"c989bce0d727de0628b3c7d4b9effc5fb34621ab","unresolved":false,"context_lines":[{"line_number":3,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":4,"context_line":""},{"line_number":5,"context_line":"NexentaStor is an Open Source-driven Software-Defined Storage (OpenSDS)"},{"line_number":6,"context_line":"platform delivering unified file (NFS and SMB) and block (FC and iSCSI)"},{"line_number":7,"context_line":"storage services. NexentaStor runs on industry standard hardware, scales from"},{"line_number":8,"context_line":"tens of terabytes to petabyte configurations, and includes all data management"},{"line_number":9,"context_line":"functionality by default."}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_0f225052","line":6,"range":{"start_line":6,"start_character":52,"end_line":6,"end_character":57},"in_reply_to":"5a18252c_f161e8a9","updated":"2016-04-13 17:24:25.000000000","message":"Do I need to use capital letters here?","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"a0ab3fae102d43290b4c47ea87d4b8150b841feb","unresolved":false,"context_lines":[{"line_number":35,"context_line":"~~~~~~~~~~~~"},{"line_number":36,"context_line":""},{"line_number":37,"context_line":"The NexentaStor appliance must be installed and configured according to the"},{"line_number":38,"context_line":"relevant Nexenta documentation. A pool and an enclosing namespace must be"},{"line_number":39,"context_line":"created for all iSCSI volumes to be accessed through the volume driver. This"},{"line_number":40,"context_line":"should be done as specified in the release-specific NexentaStor documentation."},{"line_number":41,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_b1681089","line":38,"range":{"start_line":38,"start_character":17,"end_line":38,"end_character":30},"updated":"2016-04-13 04:10:20.000000000","message":"A link to this would be helpful :) \nYes, definitely... especially seeing as you reference it a second time.","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":15439,"name":"Alexey Khodos","email":"akhodos@ddn.com","username":"Alexey"},"change_message_id":"c989bce0d727de0628b3c7d4b9effc5fb34621ab","unresolved":false,"context_lines":[{"line_number":35,"context_line":"~~~~~~~~~~~~"},{"line_number":36,"context_line":""},{"line_number":37,"context_line":"The NexentaStor appliance must be installed and configured according to the"},{"line_number":38,"context_line":"relevant Nexenta documentation. A pool and an enclosing namespace must be"},{"line_number":39,"context_line":"created for all iSCSI volumes to be accessed through the volume driver. This"},{"line_number":40,"context_line":"should be done as specified in the release-specific NexentaStor documentation."},{"line_number":41,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_4faf2881","line":38,"range":{"start_line":38,"start_character":17,"end_line":38,"end_character":30},"in_reply_to":"5a18252c_b1681089","updated":"2016-04-13 17:24:25.000000000","message":"There is a link to NexentaStor documentation in the top section of this doc, do I need to duplicate?","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a6c5d37ef3b1f4b82cae4a45b0aa748385999bc5","unresolved":false,"context_lines":[{"line_number":42,"context_line":"The NexentaStor Appliance iSCSI driver is selected using the normal procedures"},{"line_number":43,"context_line":"for one or multiple back-end volume drivers."},{"line_number":44,"context_line":""},{"line_number":45,"context_line":""},{"line_number":46,"context_line":"You must configure these items for each NexentaStor appliance that the iSCSI"},{"line_number":47,"context_line":"volume driver controls:"},{"line_number":48,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_868af8bd","line":45,"updated":"2016-04-13 03:40:59.000000000","message":"One less line space here.","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":15439,"name":"Alexey Khodos","email":"akhodos@ddn.com","username":"Alexey"},"change_message_id":"c989bce0d727de0628b3c7d4b9effc5fb34621ab","unresolved":false,"context_lines":[{"line_number":42,"context_line":"The NexentaStor Appliance iSCSI driver is selected using the normal procedures"},{"line_number":43,"context_line":"for one or multiple back-end volume drivers."},{"line_number":44,"context_line":""},{"line_number":45,"context_line":""},{"line_number":46,"context_line":"You must configure these items for each NexentaStor appliance that the iSCSI"},{"line_number":47,"context_line":"volume driver controls:"},{"line_number":48,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_afb4fcd0","line":45,"in_reply_to":"5a18252c_868af8bd","updated":"2016-04-13 17:24:25.000000000","message":"Done","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"a6c5d37ef3b1f4b82cae4a45b0aa748385999bc5","unresolved":false,"context_lines":[{"line_number":61,"context_line":"      nexenta_rest_port\u003d8080"},{"line_number":62,"context_line":""},{"line_number":63,"context_line":"      # Username for NexentaStor Rest (string value)"},{"line_number":64,"context_line":"      nexenta_user\u003dUSERNAME"},{"line_number":65,"context_line":""},{"line_number":66,"context_line":"      # Password for NexentaStor Rest (string value)"},{"line_number":67,"context_line":"      nexenta_password\u003dPASSWORD"}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_26a32451","line":64,"updated":"2016-04-13 03:40:59.000000000","message":"Remove some of the spaces here to consistently space this step in the procedure code-block.","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"a0ab3fae102d43290b4c47ea87d4b8150b841feb","unresolved":false,"context_lines":[{"line_number":98,"context_line":"relevant Nexenta documentation. A single-parent file system must be created"},{"line_number":99,"context_line":"for all virtual disk directories supported for OpenStack."},{"line_number":100,"context_line":"Create and export the directory on each NexentaStor appliance."},{"line_number":101,"context_line":""},{"line_number":102,"context_line":"For more information on NexentaStor configuration and specs, please visit"},{"line_number":103,"context_line":"http://docs.nexenta.com/"},{"line_number":104,"context_line":""},{"line_number":105,"context_line":"You must configure these items for each NexentaStor appliance that the NFS"},{"line_number":106,"context_line":"volume driver controls:"}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_112d8446","line":103,"range":{"start_line":101,"start_character":0,"end_line":103,"end_character":24},"updated":"2016-04-13 04:10:20.000000000","message":"I think move this up to the original mention of docs :)","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":15439,"name":"Alexey Khodos","email":"akhodos@ddn.com","username":"Alexey"},"change_message_id":"c989bce0d727de0628b3c7d4b9effc5fb34621ab","unresolved":false,"context_lines":[{"line_number":98,"context_line":"relevant Nexenta documentation. A single-parent file system must be created"},{"line_number":99,"context_line":"for all virtual disk directories supported for OpenStack."},{"line_number":100,"context_line":"Create and export the directory on each NexentaStor appliance."},{"line_number":101,"context_line":""},{"line_number":102,"context_line":"For more information on NexentaStor configuration and specs, please visit"},{"line_number":103,"context_line":"http://docs.nexenta.com/"},{"line_number":104,"context_line":""},{"line_number":105,"context_line":"You must configure these items for each NexentaStor appliance that the NFS"},{"line_number":106,"context_line":"volume driver controls:"}],"source_content_type":"text/x-rst","patch_set":2,"id":"5a18252c_2fc10c2f","line":103,"range":{"start_line":101,"start_character":0,"end_line":103,"end_character":24},"in_reply_to":"5a18252c_112d8446","updated":"2016-04-13 17:24:25.000000000","message":"Done","commit_id":"e682da5f6d74662bd0642d8a965e5c55d80a9c91"},{"author":{"_account_id":10897,"name":"Joseph Robinson","email":"josephremail@gmail.com","username":"RobiJoe"},"change_message_id":"ffef3aad7e09834393aaebbfc95f2d26a958fef2","unresolved":false,"context_lines":[{"line_number":77,"context_line":"      nexenta_volume represents a zpool, which is called pool on NS 5.x appliance."},{"line_number":78,"context_line":"      It must be pre-created before enabling the driver."},{"line_number":79,"context_line":""},{"line_number":80,"context_line":"      Volume group does not need to be pre-created, the driver will create it if does not exist."},{"line_number":81,"context_line":""},{"line_number":82,"context_line":"#. Save the changes to the ``/etc/cinder/cinder.conf`` file and"},{"line_number":83,"context_line":"   restart the ``cinder-volume`` service."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5a18252c_ae6ce635","line":80,"updated":"2016-04-14 07:07:38.000000000","message":"Switch \u0027Volume group\u0027 for ``nexenta_volume_group`` here.","commit_id":"64df360ea6883c3110484a24c34a76c3f18ad7ce"},{"author":{"_account_id":15439,"name":"Alexey Khodos","email":"akhodos@ddn.com","username":"Alexey"},"change_message_id":"d20b9351dfd771ccd117e91f8dda31bff77e630c","unresolved":false,"context_lines":[{"line_number":77,"context_line":"      nexenta_volume represents a zpool, which is called pool on NS 5.x appliance."},{"line_number":78,"context_line":"      It must be pre-created before enabling the driver."},{"line_number":79,"context_line":""},{"line_number":80,"context_line":"      Volume group does not need to be pre-created, the driver will create it if does not exist."},{"line_number":81,"context_line":""},{"line_number":82,"context_line":"#. Save the changes to the ``/etc/cinder/cinder.conf`` file and"},{"line_number":83,"context_line":"   restart the ``cinder-volume`` service."}],"source_content_type":"text/x-rst","patch_set":3,"id":"5a18252c_ab2aeb8d","line":80,"in_reply_to":"5a18252c_ae6ce635","updated":"2016-04-14 18:03:24.000000000","message":"nexenta_volume_group is a config opt, while volume group here is about NS appliance where it is called volume group","commit_id":"64df360ea6883c3110484a24c34a76c3f18ad7ce"}]}
