{"doc/ha-guide-draft/source/intro-ha-common-tech.rst":[{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":3,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_bbfa1dba","line":6,"range":{"start_line":6,"start_character":0,"end_line":6,"end_character":28},"updated":"2017-07-17 12:33:53.000000000","message":"This document lists the most common *","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":3,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_0421b2b0","line":6,"range":{"start_line":6,"start_character":0,"end_line":6,"end_character":28},"in_reply_to":"1f1a1f67_bbfa1dba","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_1b35918f","line":7,"range":{"start_line":7,"start_character":29,"end_line":7,"end_character":33},"updated":"2017-07-17 12:33:53.000000000","message":"highly *","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_3b304d9f","line":7,"range":{"start_line":7,"start_character":0,"end_line":7,"end_character":5},"updated":"2017-07-17 12:33:53.000000000","message":"that","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_64050614","line":7,"range":{"start_line":7,"start_character":29,"end_line":7,"end_character":33},"in_reply_to":"1f1a1f67_1b35918f","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":4,"context_line":"High availability can be achieved only on system level, while both hardware and"},{"line_number":5,"context_line":"software components can contribute to the system level availability."},{"line_number":6,"context_line":"In the next chapters we list the most common hardware and software technologies"},{"line_number":7,"context_line":"which can be used to build a high available system."},{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_2f012706","line":7,"range":{"start_line":7,"start_character":0,"end_line":7,"end_character":5},"in_reply_to":"1f1a1f67_3b304d9f","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_9b20814a","line":11,"range":{"start_line":11,"start_character":47,"end_line":11,"end_character":54},"updated":"2017-07-17 12:33:53.000000000","message":"remove","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_bb233d56","line":11,"range":{"start_line":11,"start_character":0,"end_line":11,"end_character":18},"updated":"2017-07-17 12:33:53.000000000","message":"what technologies? :)","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_cf72b3ad","line":11,"range":{"start_line":11,"start_character":47,"end_line":11,"end_character":54},"in_reply_to":"1f1a1f67_9b20814a","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_cfa7530b","line":11,"range":{"start_line":11,"start_character":0,"end_line":11,"end_character":18},"in_reply_to":"1f1a1f67_bb233d56","updated":"2017-07-17 14:14:00.000000000","message":"The different technologies we will discuss in the following chapters. I\u0027ve added one explainig sentence, but I\u0027m not sure if the result is better :)","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"},{"line_number":15,"context_line":"------------------"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_7b192520","line":12,"range":{"start_line":12,"start_character":34,"end_line":12,"end_character":37},"updated":"2017-07-17 12:33:53.000000000","message":"highly *","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using technologies to enable high availability already on hardware level"},{"line_number":12,"context_line":"provides a good basis to build a high available system."},{"line_number":13,"context_line":""},{"line_number":14,"context_line":"Redundant switches"},{"line_number":15,"context_line":"------------------"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_4fb3434e","line":12,"range":{"start_line":12,"start_character":34,"end_line":12,"end_character":37},"in_reply_to":"1f1a1f67_7b192520","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":14,"context_line":"Redundant switches"},{"line_number":15,"context_line":"------------------"},{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_5b99c976","line":18,"range":{"start_line":17,"start_character":45,"end_line":18,"end_character":15},"updated":"2017-07-17 12:33:53.000000000","message":"not too sure what you mean here?","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":15,"context_line":"------------------"},{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_db86f913","line":18,"range":{"start_line":18,"start_character":33,"end_line":18,"end_character":46},"updated":"2017-07-17 12:33:53.000000000","message":"remove","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":14,"context_line":"Redundant switches"},{"line_number":15,"context_line":"------------------"},{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_ef7b2f78","line":18,"range":{"start_line":17,"start_character":45,"end_line":18,"end_character":15},"in_reply_to":"1f1a1f67_5b99c976","updated":"2017-07-17 14:14:00.000000000","message":"Without networking you can not start a VM or you can not synchronise storage data.","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"},{"line_number":22,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_9b7c0120","line":19,"range":{"start_line":19,"start_character":15,"end_line":19,"end_character":25},"updated":"2017-07-17 12:33:53.000000000","message":"and be able to forward *","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"},{"line_number":22,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_7b75a531","line":19,"range":{"start_line":19,"start_character":57,"end_line":19,"end_character":78},"updated":"2017-07-17 12:33:53.000000000","message":"could you be more specific here?","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":16,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"},{"line_number":22,"context_line":""}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_afde576a","line":19,"range":{"start_line":19,"start_character":57,"end_line":19,"end_character":78},"in_reply_to":"1f1a1f67_7b75a531","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":17,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":18,"context_line":"infrastructure. Network switches also not only need to be able forward the"},{"line_number":19,"context_line":"network traffic, but they need to be able to forward the traffic to somewhere."},{"line_number":20,"context_line":"For these reasons to make a network switch redundant the following two factors"},{"line_number":21,"context_line":"should be considered:"},{"line_number":22,"context_line":""},{"line_number":23,"context_line":"#. The network switch itself should synchronize its internal state to a"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_bba45da7","line":20,"range":{"start_line":20,"start_character":10,"end_line":20,"end_character":17},"updated":"2017-07-17 12:33:53.000000000","message":"reasons, consider the following two factors when making a network switch redundant:*","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":29,"context_line":"Bonded interfaces"},{"line_number":30,"context_line":"-----------------"},{"line_number":31,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":32,"context_line":"one interface in active/passive mode. In case of an error in the active network"},{"line_number":33,"context_line":"interface itself or in the remote end of the interface the interfaces are"},{"line_number":34,"context_line":"switched over."},{"line_number":35,"context_line":""},{"line_number":36,"context_line":"Load balancers"},{"line_number":37,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_3bba8dc0","line":34,"range":{"start_line":32,"start_character":38,"end_line":34,"end_character":14},"updated":"2017-07-17 12:33:53.000000000","message":"Not too sure what this is meant to be saying? Could you clarify?","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":29,"context_line":"Bonded interfaces"},{"line_number":30,"context_line":"-----------------"},{"line_number":31,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":32,"context_line":"one interface in active/passive mode. In case of an error in the active network"},{"line_number":33,"context_line":"interface itself or in the remote end of the interface the interfaces are"},{"line_number":34,"context_line":"switched over."},{"line_number":35,"context_line":""},{"line_number":36,"context_line":"Load balancers"},{"line_number":37,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_af96574b","line":34,"range":{"start_line":32,"start_character":38,"end_line":34,"end_character":14},"in_reply_to":"1f1a1f67_3bba8dc0","updated":"2017-07-17 14:14:00.000000000","message":"If the active interface is down or its connection is down then the bond starts to use the other interface automatically.","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":10607,"name":"Alexandra Settle","email":"a.settle@outlook.com","username":"asettle"},"change_message_id":"903af97c6ef66641cef9363bb213bf1a640a7ee7","unresolved":false,"context_lines":[{"line_number":43,"context_line":""},{"line_number":44,"context_line":"Storage"},{"line_number":45,"context_line":"-------"},{"line_number":46,"context_line":"Physical storage high availability can be achieved with different scope:"},{"line_number":47,"context_line":""},{"line_number":48,"context_line":"#. High availability within a hardware unit with redundant disks (mostly"},{"line_number":49,"context_line":"   organized into different RAID configurations), redundant control components,"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_bbcd7d67","line":46,"range":{"start_line":46,"start_character":66,"end_line":46,"end_character":72},"updated":"2017-07-17 12:33:53.000000000","message":"scopes*","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"0db137758e8dd201d3892f4b1424f492dd7d5a45","unresolved":false,"context_lines":[{"line_number":43,"context_line":""},{"line_number":44,"context_line":"Storage"},{"line_number":45,"context_line":"-------"},{"line_number":46,"context_line":"Physical storage high availability can be achieved with different scope:"},{"line_number":47,"context_line":""},{"line_number":48,"context_line":"#. High availability within a hardware unit with redundant disks (mostly"},{"line_number":49,"context_line":"   organized into different RAID configurations), redundant control components,"}],"source_content_type":"text/x-rst","patch_set":2,"id":"1f1a1f67_ef81effc","line":46,"range":{"start_line":46,"start_character":66,"end_line":46,"end_character":72},"in_reply_to":"1f1a1f67_bbcd7d67","updated":"2017-07-17 14:14:00.000000000","message":"Done","commit_id":"b9dd7c66aaad566ca74c53ca7093a46f4feba767"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"f0474e655052e90d187a3b9bee56a56d001ca56c","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using different technologies to enable high availability on the hardware"},{"line_number":12,"context_line":"level provides a good basis to build a high available system. The next chapters"},{"line_number":13,"context_line":"discuss the most common technologies used in this field."},{"line_number":14,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_a749d6b7","line":11,"updated":"2017-07-17 19:29:40.000000000","message":"If there is a good reason to remove the information about provider / self-service networks, please can you justify it in the commit message? Currently the commit message only mentions what is added, not what is removed. Thanks!","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"8e4e21911874933f19a4e25cd76a2cca15caec83","unresolved":false,"context_lines":[{"line_number":8,"context_line":""},{"line_number":9,"context_line":"Hardware"},{"line_number":10,"context_line":"~~~~~~~~"},{"line_number":11,"context_line":"Using different technologies to enable high availability on the hardware"},{"line_number":12,"context_line":"level provides a good basis to build a high available system. The next chapters"},{"line_number":13,"context_line":"discuss the most common technologies used in this field."},{"line_number":14,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_62295ae4","line":11,"in_reply_to":"1f1a1f67_a749d6b7","updated":"2017-07-18 08:58:03.000000000","message":"I think the networking options are not related to hardware HA. I will explain this in the commit message.","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"f0474e655052e90d187a3b9bee56a56d001ca56c","unresolved":false,"context_lines":[{"line_number":25,"context_line":"   redundant switch either in active/active or active/passive way."},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"#. The network topology should be designed in a way the the network router can"},{"line_number":28,"context_line":"   use at least two path in every critical direction."},{"line_number":29,"context_line":""},{"line_number":30,"context_line":"Bonded interfaces"},{"line_number":31,"context_line":"-----------------"}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_47320260","line":28,"range":{"start_line":28,"start_character":20,"end_line":28,"end_character":24},"updated":"2017-07-17 19:29:40.000000000","message":"\"paths\"","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"8e4e21911874933f19a4e25cd76a2cca15caec83","unresolved":false,"context_lines":[{"line_number":25,"context_line":"   redundant switch either in active/active or active/passive way."},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"#. The network topology should be designed in a way the the network router can"},{"line_number":28,"context_line":"   use at least two path in every critical direction."},{"line_number":29,"context_line":""},{"line_number":30,"context_line":"Bonded interfaces"},{"line_number":31,"context_line":"-----------------"}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_c2682e1e","line":28,"range":{"start_line":28,"start_character":20,"end_line":28,"end_character":24},"in_reply_to":"1f1a1f67_47320260","updated":"2017-07-18 08:58:03.000000000","message":"Done","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"f0474e655052e90d187a3b9bee56a56d001ca56c","unresolved":false,"context_lines":[{"line_number":30,"context_line":"Bonded interfaces"},{"line_number":31,"context_line":"-----------------"},{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive mode. In case of an error in the active network"},{"line_number":34,"context_line":"interface or in the remote end of the interface the interfaces are"},{"line_number":35,"context_line":"switched over."},{"line_number":36,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_c773b215","line":33,"range":{"start_line":33,"start_character":14,"end_line":33,"end_character":36},"updated":"2017-07-17 19:29:40.000000000","message":"This is not entirely accurate - whilst bonding can be configured in active/passive mode, Linux also supports 6 different active/active bonding modes:\n\nhttps://www.kernel.org/doc/Documentation/networking/bonding.txt","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"8e4e21911874933f19a4e25cd76a2cca15caec83","unresolved":false,"context_lines":[{"line_number":30,"context_line":"Bonded interfaces"},{"line_number":31,"context_line":"-----------------"},{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive mode. In case of an error in the active network"},{"line_number":34,"context_line":"interface or in the remote end of the interface the interfaces are"},{"line_number":35,"context_line":"switched over."},{"line_number":36,"context_line":""}],"source_content_type":"text/x-rst","patch_set":3,"id":"1f1a1f67_62615a05","line":33,"range":{"start_line":33,"start_character":14,"end_line":33,"end_character":36},"in_reply_to":"1f1a1f67_c773b215","updated":"2017-07-18 08:58:03.000000000","message":"Done","commit_id":"f2b684104e446ea8a2891923fc56bf4d1de19b68"},{"author":{"_account_id":22406,"name":"Kien Nguyen","email":"kiennt2609@gmail.com","username":"kiennt"},"change_message_id":"177ae9260e934d411f4d40dd4c117c0125cf2839","unresolved":false,"context_lines":[{"line_number":14,"context_line":""},{"line_number":15,"context_line":"Redundant switches"},{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_0d8f7775","line":17,"range":{"start_line":17,"start_character":17,"end_line":17,"end_character":34},"updated":"2017-07-18 09:06:01.000000000","message":"s/are easily become/easily become/g","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":14,"context_line":""},{"line_number":15,"context_line":"Redundant switches"},{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_42141944","line":17,"range":{"start_line":17,"start_character":17,"end_line":17,"end_character":34},"in_reply_to":"1f1a1f67_0d8f7775","updated":"2017-07-18 11:05:36.000000000","message":"Personally I would drop \"become\" altogether, since generally network switches are either SPoF at the time they are installed, or never SPoF. I suspect it\u0027s rare that they would start off by not being SPoF at installation time, and then \"become\" SPoF later. (Note that a device does not become a SPoF at the time of the first failure; by definition it is a SPoF if its own failure can cause everything else to fail, even if that failure never happens.)","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":14,"context_line":""},{"line_number":15,"context_line":"Redundant switches"},{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ae4f2669","line":17,"range":{"start_line":17,"start_character":17,"end_line":17,"end_character":34},"in_reply_to":"1f1a1f67_42141944","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":15,"context_line":"Redundant switches"},{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."},{"line_number":21,"context_line":"For these reasons consider the following two factors when making a network"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_62595533","line":18,"range":{"start_line":18,"start_character":45,"end_line":18,"end_character":69},"updated":"2017-07-18 11:05:36.000000000","message":"IMHO this clause disrupts the flow of this sentence.  I think it reads better if you put it at the end:\n\nNetwork switches can easily be single point of failures since networking is critical for correct operation of all other basic domains of the infrastructure, such as compute and storage.","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":15,"context_line":"Redundant switches"},{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."},{"line_number":21,"context_line":"For these reasons consider the following two factors when making a network"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ce43823e","line":18,"range":{"start_line":18,"start_character":45,"end_line":18,"end_character":69},"in_reply_to":"1f1a1f67_62595533","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":22406,"name":"Kien Nguyen","email":"kiennt2609@gmail.com","username":"kiennt"},"change_message_id":"177ae9260e934d411f4d40dd4c117c0125cf2839","unresolved":false,"context_lines":[{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."},{"line_number":21,"context_line":"For these reasons consider the following two factors when making a network"},{"line_number":22,"context_line":"switch redundant:"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_2ddb537c","line":19,"range":{"start_line":19,"start_character":44,"end_line":19,"end_character":48},"updated":"2017-07-18 09:06:01.000000000","message":"s/able/able to/g","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":16,"context_line":"------------------"},{"line_number":17,"context_line":"Network switches are easily become single point of failures as networking is"},{"line_number":18,"context_line":"critical to operate all other basic domains, like compute and storage, of the"},{"line_number":19,"context_line":"infrastructure. Network switches need to be able forward the network traffic"},{"line_number":20,"context_line":"and be able to forward the traffic to a working next hop."},{"line_number":21,"context_line":"For these reasons consider the following two factors when making a network"},{"line_number":22,"context_line":"switch redundant:"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ae78468f","line":19,"range":{"start_line":19,"start_character":44,"end_line":19,"end_character":48},"in_reply_to":"1f1a1f67_2ddb537c","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":22406,"name":"Kien Nguyen","email":"kiennt2609@gmail.com","username":"kiennt"},"change_message_id":"177ae9260e934d411f4d40dd4c117c0125cf2839","unresolved":false,"context_lines":[{"line_number":24,"context_line":"#. The network switch itself should synchronize its internal state to a"},{"line_number":25,"context_line":"   redundant switch either in active/active or active/passive way."},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"#. The network topology should be designed in a way the the network router can"},{"line_number":28,"context_line":"   use at least two paths in every critical direction."},{"line_number":29,"context_line":""},{"line_number":30,"context_line":"Bonded interfaces"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_0de4173b","line":27,"range":{"start_line":27,"start_character":52,"end_line":27,"end_character":59},"updated":"2017-07-18 09:06:01.000000000","message":"duplicate","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":24,"context_line":"#. The network switch itself should synchronize its internal state to a"},{"line_number":25,"context_line":"   redundant switch either in active/active or active/passive way."},{"line_number":26,"context_line":""},{"line_number":27,"context_line":"#. The network topology should be designed in a way the the network router can"},{"line_number":28,"context_line":"   use at least two paths in every critical direction."},{"line_number":29,"context_line":""},{"line_number":30,"context_line":"Bonded interfaces"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ce5ca21a","line":27,"range":{"start_line":27,"start_character":52,"end_line":27,"end_character":59},"in_reply_to":"1f1a1f67_0de4173b","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":31,"context_line":"-----------------"},{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_a27c0d83","line":34,"range":{"start_line":34,"start_character":15,"end_line":34,"end_character":22},"updated":"2017-07-18 11:05:36.000000000","message":"\"... mode, if ...\"","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":31,"context_line":"-----------------"},{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_2eb1d647","line":34,"range":{"start_line":34,"start_character":15,"end_line":34,"end_character":22},"in_reply_to":"1f1a1f67_a27c0d83","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_2268fdb6","line":35,"range":{"start_line":35,"start_character":18,"end_line":35,"end_character":46},"updated":"2017-07-18 11:05:36.000000000","message":"\"the interface, the interfaces\"","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":32,"context_line":"Bonded interfaces are two independent physical network interfaces handled as"},{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_0eacdaea","line":35,"range":{"start_line":35,"start_character":18,"end_line":35,"end_character":46},"in_reply_to":"1f1a1f67_2268fdb6","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_02b6213f","line":36,"range":{"start_line":36,"start_character":14,"end_line":36,"end_character":23},"updated":"2017-07-18 11:05:36.000000000","message":"\"... mode, when ...\"","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":33,"context_line":"one interface in active/passive or in active/active redundancy mode. In"},{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ceb14246","line":36,"range":{"start_line":36,"start_character":14,"end_line":36,"end_character":23},"in_reply_to":"1f1a1f67_02b6213f","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":22406,"name":"Kien Nguyen","email":"kiennt2609@gmail.com","username":"kiennt"},"change_message_id":"177ae9260e934d411f4d40dd4c117c0125cf2839","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_add8837a","line":37,"range":{"start_line":37,"start_character":16,"end_line":37,"end_character":23},"updated":"2017-07-18 09:06:01.000000000","message":"duplicate","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_2ec8b6a3","line":37,"range":{"start_line":37,"start_character":16,"end_line":37,"end_character":23},"in_reply_to":"1f1a1f67_add8837a","updated":"2017-07-19 14:12:44.000000000","message":"Adams suggestion what I implemented solves this.","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_c285c95b","line":37,"range":{"start_line":37,"start_character":16,"end_line":37,"end_character":23},"in_reply_to":"1f1a1f67_add8837a","updated":"2017-07-18 11:05:36.000000000","message":"In this case it\u0027s not really considered as passive, because that implies that it is available for failover, which is not true because it has already failed.  Also needs a comma.  I suggest\n\n\"... an interface, the interface is marked as unavailable and ceases to be used.\"\n\nThe commas make it easier to parse these sentences.","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface the the interface is considered as passive."},{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_cedf0264","line":37,"range":{"start_line":37,"start_character":16,"end_line":37,"end_character":23},"in_reply_to":"1f1a1f67_c285c95b","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"},{"line_number":41,"context_line":"Physical load balancers are special routers which are directing the traffic to"},{"line_number":42,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":43,"context_line":"redundant mode similarly to the physical switches."},{"line_number":44,"context_line":"Load balancers are also important to distribute the traffic to the different"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_c2ea690d","line":41,"range":{"start_line":41,"start_character":50,"end_line":41,"end_character":78},"updated":"2017-07-18 11:05:36.000000000","message":"\"... direct the traffic in ...\"","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":38,"context_line":""},{"line_number":39,"context_line":"Load balancers"},{"line_number":40,"context_line":"--------------"},{"line_number":41,"context_line":"Physical load balancers are special routers which are directing the traffic to"},{"line_number":42,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":43,"context_line":"redundant mode similarly to the physical switches."},{"line_number":44,"context_line":"Load balancers are also important to distribute the traffic to the different"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_4e42d210","line":41,"range":{"start_line":41,"start_character":50,"end_line":41,"end_character":78},"in_reply_to":"1f1a1f67_c2ea690d","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":2394,"name":"Adam Spiers","email":"aspiers@suse.com","username":"adam.spiers"},"change_message_id":"395dfcffbba816a2ba9929b348f55b7c20fe5f06","unresolved":false,"context_lines":[{"line_number":41,"context_line":"Physical load balancers are special routers which are directing the traffic to"},{"line_number":42,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":43,"context_line":"redundant mode similarly to the physical switches."},{"line_number":44,"context_line":"Load balancers are also important to distribute the traffic to the different"},{"line_number":45,"context_line":"active/active components of the system."},{"line_number":46,"context_line":""},{"line_number":47,"context_line":"Storage"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_82f0f1fe","line":44,"range":{"start_line":44,"start_character":24,"end_line":44,"end_character":47},"updated":"2017-07-18 11:05:36.000000000","message":"\"... important for distributing ...\"","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"545db50cd46a83d0452f9fa4a47e54ab0da99ec1","unresolved":false,"context_lines":[{"line_number":41,"context_line":"Physical load balancers are special routers which are directing the traffic to"},{"line_number":42,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":43,"context_line":"redundant mode similarly to the physical switches."},{"line_number":44,"context_line":"Load balancers are also important to distribute the traffic to the different"},{"line_number":45,"context_line":"active/active components of the system."},{"line_number":46,"context_line":""},{"line_number":47,"context_line":"Storage"}],"source_content_type":"text/x-rst","patch_set":4,"id":"1f1a1f67_ce4dc23b","line":44,"range":{"start_line":44,"start_character":24,"end_line":44,"end_character":47},"in_reply_to":"1f1a1f67_82f0f1fe","updated":"2017-07-19 14:12:44.000000000","message":"Done","commit_id":"95f0f648b452161d583d71d4b2598b66d1bf2003"},{"author":{"_account_id":20156,"name":"Petr Kovar","email":"pkovar@redhat.com","username":"pmkovar"},"change_message_id":"adb4a6ba7704e3333349715a13480dec0dbb6525","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode, if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface, the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode, when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface, than the interface is marked as unavailable and ceases to be"},{"line_number":38,"context_line":"used."},{"line_number":39,"context_line":""},{"line_number":40,"context_line":"Load balancers"}],"source_content_type":"text/x-rst","patch_set":5,"id":"1f1a1f67_4123c0a7","line":37,"range":{"start_line":37,"start_character":17,"end_line":37,"end_character":21},"updated":"2017-07-19 16:38:17.000000000","message":"then","commit_id":"b6107c6c9943b8e87735d4cf69845f5e86031a38"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"6f78ff61a1c4a01e4e698911b046d76b9538b9ec","unresolved":false,"context_lines":[{"line_number":34,"context_line":"active/passive mode, if an error happens in the active network interface or in"},{"line_number":35,"context_line":"the remote end of the interface, the interfaces are switched over. In"},{"line_number":36,"context_line":"active/active mode, when an error happens in an interface or in the remote end"},{"line_number":37,"context_line":"of an interface, than the interface is marked as unavailable and ceases to be"},{"line_number":38,"context_line":"used."},{"line_number":39,"context_line":""},{"line_number":40,"context_line":"Load balancers"}],"source_content_type":"text/x-rst","patch_set":5,"id":"1f1a1f67_01aca8ea","line":37,"range":{"start_line":37,"start_character":17,"end_line":37,"end_character":21},"in_reply_to":"1f1a1f67_4123c0a7","updated":"2017-07-19 16:44:14.000000000","message":"Done","commit_id":"b6107c6c9943b8e87735d4cf69845f5e86031a38"},{"author":{"_account_id":20156,"name":"Petr Kovar","email":"pkovar@redhat.com","username":"pmkovar"},"change_message_id":"adb4a6ba7704e3333349715a13480dec0dbb6525","unresolved":false,"context_lines":[{"line_number":39,"context_line":""},{"line_number":40,"context_line":"Load balancers"},{"line_number":41,"context_line":"--------------"},{"line_number":42,"context_line":"Physical load balancers are special routers which are direct the traffic in"},{"line_number":43,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":44,"context_line":"redundant mode similarly to the physical switches."},{"line_number":45,"context_line":"Load balancers are also important for distributing the traffic to the different"}],"source_content_type":"text/x-rst","patch_set":5,"id":"1f1a1f67_21156440","line":42,"range":{"start_line":42,"start_character":50,"end_line":42,"end_character":53},"updated":"2017-07-19 16:38:17.000000000","message":"Remove.","commit_id":"b6107c6c9943b8e87735d4cf69845f5e86031a38"},{"author":{"_account_id":21723,"name":"Gergely Csatari","email":"gergely.csatari@nokia.com","username":"csatari"},"change_message_id":"6f78ff61a1c4a01e4e698911b046d76b9538b9ec","unresolved":false,"context_lines":[{"line_number":39,"context_line":""},{"line_number":40,"context_line":"Load balancers"},{"line_number":41,"context_line":"--------------"},{"line_number":42,"context_line":"Physical load balancers are special routers which are direct the traffic in"},{"line_number":43,"context_line":"different directions based on a set of rules. Load balancers can be in"},{"line_number":44,"context_line":"redundant mode similarly to the physical switches."},{"line_number":45,"context_line":"Load balancers are also important for distributing the traffic to the different"}],"source_content_type":"text/x-rst","patch_set":5,"id":"1f1a1f67_8189d875","line":42,"range":{"start_line":42,"start_character":50,"end_line":42,"end_character":53},"in_reply_to":"1f1a1f67_21156440","updated":"2017-07-19 16:44:14.000000000","message":"Done","commit_id":"b6107c6c9943b8e87735d4cf69845f5e86031a38"}]}