{"deployment/ironic/ironic-conductor-container-puppet.yaml":[{"author":{"_account_id":13861,"name":"yatin","email":"ykarel@redhat.com","username":"yatinkarel"},"change_message_id":"58fbb3e399a54b2625aee62824876cb2f844feb0","unresolved":false,"context_lines":[{"line_number":346,"context_line":"            if:"},{"line_number":347,"context_line":"            - enable_architecture_ppc64le"},{"line_number":348,"context_line":"            - ironic::pxe::enable_ppc64le: true"},{"line_number":349,"context_line":"              ironic::conductor::power_state_change_timeout: 90"},{"line_number":350,"context_line":"              ironic::conductor::sync_power_state_interval: 120"},{"line_number":351,"context_line":"              ironic::drivers::ipmi::command_retry_timeout: 120"},{"line_number":352,"context_line":"              ironic::drivers::ipmi::min_command_interval: 15"}],"source_content_type":"text/x-yaml","patch_set":1,"id":"9f560f44_77e590a4","line":349,"updated":"2020-09-28 14:35:15.000000000","message":"the configs here are not being used as it\u0027s for ppc arch only. Also seems it\u0027s happening post https://review.opendev.org/#/c/749845/, so need to try setting new config option for inspector https://review.opendev.org/#/c/749845/3/ironic_inspector/conf/default.py, if these points are true, changing conductor options likely not help.","commit_id":"a9ff96b783701a6e7182190d065aebb820caa34b"},{"author":{"_account_id":24245,"name":"Harald Jensås","email":"hjensas@redhat.com","username":"harald.jensas"},"change_message_id":"06be2d4bb476040668548e687ca4232b46a7401e","unresolved":false,"context_lines":[{"line_number":346,"context_line":"            if:"},{"line_number":347,"context_line":"            - enable_architecture_ppc64le"},{"line_number":348,"context_line":"            - ironic::pxe::enable_ppc64le: true"},{"line_number":349,"context_line":"              ironic::conductor::power_state_change_timeout: 90"},{"line_number":350,"context_line":"              ironic::conductor::sync_power_state_interval: 120"},{"line_number":351,"context_line":"              ironic::drivers::ipmi::command_retry_timeout: 120"},{"line_number":352,"context_line":"              ironic::drivers::ipmi::min_command_interval: 15"}],"source_content_type":"text/x-yaml","patch_set":1,"id":"9f560f44_c6394c41","line":349,"in_reply_to":"9f560f44_77e590a4","updated":"2020-09-28 17:51:49.000000000","message":"yatin is right, I was\u0027nt aware of the new timeout in inspector. But it seems that is what we need to set.\n\nAlso, I will -1 this patch as we should\u0027nt change the timeouts in the product. We should change it in CI only.\n\nThis is a CI OVB issue, powering off a virtual baremetal running in openstack takes ~50-60+ seconds on my lab running OVB. With real hardware this is most typically a less than 10 seconds operation.\n\nPlease create a patch in quickstart-extras setting the power_timeout in inspector configuration.","commit_id":"a9ff96b783701a6e7182190d065aebb820caa34b"}]}