)]}'
{"specs/ocata/vitrage-id.rst":[{"author":{"_account_id":19159,"name":"Ifat Afek","email":"ifat.afek@nokia.com","username":"ifat_afek"},"change_message_id":"0b9b656a0b0ea2b597b332b5a118bf5bcde0c0b5","unresolved":false,"context_lines":[{"line_number":20,"context_line":""},{"line_number":21,"context_line":"Proposed change"},{"line_number":22,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":23,"context_line":""},{"line_number":24,"context_line":"All the documentations and examples in Vitrage project should be updated to use an OpenStack compliant UUID."},{"line_number":25,"context_line":""},{"line_number":26,"context_line":"A few Mock Json files exist for “mock api” requests purposes, for example, alarms.sample.json."}],"source_content_type":"text/x-rst","patch_set":1,"id":"9a57fde8_d243226b","line":23,"range":{"start_line":23,"start_character":0,"end_line":23,"end_character":0},"updated":"2017-01-12 08:30:18.000000000","message":"I would start with a one line explanation that you are going to change all IDs to UUID. You mentioned it in the problem description, but this is actually the change. After that first line, there are all the needed changes that you listed.","commit_id":"4dad28e6213b9827fdb9c7dac9f139d3ea6e5b0e"},{"author":{"_account_id":19159,"name":"Ifat Afek","email":"ifat.afek@nokia.com","username":"ifat_afek"},"change_message_id":"0b9b656a0b0ea2b597b332b5a118bf5bcde0c0b5","unresolved":false,"context_lines":[{"line_number":73,"context_line":"Dependencies"},{"line_number":74,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d\u003d"},{"line_number":75,"context_line":""},{"line_number":76,"context_line":"Aodh : Getting Vitrage ID from AODH : Still waiting for Metadata support in AODH . Otherwise, it won’t be"},{"line_number":77,"context_line":"supported in Vitrage."},{"line_number":78,"context_line":""},{"line_number":79,"context_line":"Testing"},{"line_number":80,"context_line":"\u003d\u003d\u003d\u003d\u003d\u003d\u003d"}],"source_content_type":"text/x-rst","patch_set":1,"id":"9a57fde8_3209ce32","line":77,"range":{"start_line":76,"start_character":0,"end_line":77,"end_character":21},"updated":"2017-01-12 08:30:18.000000000","message":"Please be more specific: \n- Aodh datasource will continue to work\n- Aodh notifier will not be supported, because we won\u0027t be able to correctly sync the alarm IDs back to Vitrage\n\nThe way you wrote it, it may sound like Aodh integration won\u0027t work at all","commit_id":"4dad28e6213b9827fdb9c7dac9f139d3ea6e5b0e"}]}
